MR-guided interventional breast procedures considering vacuum biopsy in particular

被引:35
作者
Viehweg, P [1 ]
Heinig, A [1 ]
Amaya, B [1 ]
Alberich, T [1 ]
Laniado, M [1 ]
Heywang-Köbrunner, SH [1 ]
机构
[1] Tech Univ Dresden, Inst Diagnost Radiol, D-01307 Dresden, Germany
关键词
MR; breast biopsy; intervention;
D O I
10.1016/S0720-048X(01)00479-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Histologic work-up of just MR-detected breast lesions has become essential with increasing use of contrast-enhanced MR imaging. In the present article an overview is given about the different MR-guided breast interventions, performed since 1990. Presently, for reasons of costs and image quality closed magnets are most widely used. The following approaches have been described: MR-guided freehand localization in supine position, stereotaxic localization in supine position and most frequently used localization in the prone position by means of a compression device that immobilises the breast to prevent tissue shift during intervention. Only limited experience exists with interventions on open magnets. MR-guided wire localization is a well-established procedure. Recently, percutaneous vacuum biopsy of enhancing breast lesions has become possible under MR guidance. The new system allows accurate and safe access to lesions in any location of the breast and direct check-up of representative excision by visualisation of the cavity. Thus reliable histologic evaluation of lesions smaller than 10 mm is possible with this approach. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 46 条
[41]   Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumors [J].
Jung, EM ;
Jungius, KP ;
Lenhart, M ;
Dengler, M ;
Becker, H ;
Rupp, N .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (10) :1416-1422
[42]   MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging [J].
Berger, Nicole ;
Varga, Zsuzsanna ;
Frauenfelder, Thomas ;
Boss, Andreas .
MAGNETIC RESONANCE IMAGING, 2017, 38 :1-5
[43]   Simultaneous MR-Tracking (MRT) and Voltage-Device-Tracking (VDT) -Based Navigation Inside MR Scanners by Removing VDT Gradient-Induced-Voltage (GIV) Artifacts: Facilitating Spatially-Accurate and Workflow-Efficient MR-Guided Electrophysiology Procedures [J].
Dabaghayan, Mikayel ;
De Arcos, Jose ;
Kwong, Raymond Y. ;
Stevenson, William G. ;
Schweitzer, Jeffrey ;
Olson, Gregory ;
Schmidt, Ehud J. .
CIRCULATION, 2017, 136
[44]   A comprehensive evaluation of the 8-gauge vacuum-assisted Mammotome® system for ultrasound-guided diagnostic biopsy and selective excision of breast lesions [J].
Povoski S.P. ;
Jimenez R.E. .
World Journal of Surgical Oncology, 5 (1)
[45]   Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision:: Utility and cost study in probably benign lesions [J].
Alonso-Bartolomé, P ;
Vega-Bolívar, A ;
Torres-Tabanera, M ;
Ortega, E ;
Acebal-Blanco, M ;
Garijo-Ayensa, F ;
Rodrigo, I ;
Muñoz-Cacho, P .
ACTA RADIOLOGICA, 2004, 45 (04) :390-396
[46]   MR-guided stereotactic breast biopsy using a mixed ferromagnetic- nonmagnetic coaxial system with 12- to 18-gauge needles: Clinical experience and long-term outcome; [Biopsia mammaria stereotassica RM-guidata mediante sistema coassiale misto ferromagnetico-amagnetico con aghi da 12-18 Gauge: esperienza clinica e risultati a lungo termine] [J].
Belloni E. ;
Panizza P. ;
Ravelli S. ;
De Cobelli F. ;
Gusmini S. ;
Losio C. ;
Sassi I. ;
Perseghin G. ;
Del Maschio A. .
La radiologia medica, 2013, 118 (7) :1137-1148