Test Kitchen studies of indoor air pollution from biomass cookstoves

被引:35
作者
Grabow, Kelley [1 ]
Still, Dean [1 ]
Bentson, Sam [1 ]
机构
[1] Aprovecho Res Ctr, Cottage Grove, OR 97424 USA
关键词
Air exchange rate; Biomass fuel; Indoor air pollution; Ventilation; Cookstoves; Test Kitchen; Water boiling test;
D O I
10.1016/j.esd.2013.05.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor air pollution from biomass cookstoves seriously affects human health worldwide. This study investigated the effect of increasing air exchange rates in a Test Kitchen. Opening the door and window in a Test Kitchen lowered the particulate matter (PM) 1-hour concentrations between 93 and 98% compared to the closed kitchen, and the carbon monoxide (CO) 1-hour concentrations were 83 to 95% lower. (C) 2013 International Energy Initiative. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:458 / 462
页数:5
相关论文
共 14 条
[1]   Field testing and survey evaluation of household biomass cookstoves in rural sub-Saharan Africa [J].
Adkins, Edwin ;
Tyler, Erika ;
Wang, Jin ;
Siriri, David ;
Modi, Vijay .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2010, 14 (03) :172-185
[2]  
[Anonymous], 2013, WBT 4 2 1
[3]  
Barnes B., 2006, Boiling Point, P11
[4]   Smoke-reduction technologies in developing countries [J].
Bates, L .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-MUNICIPAL ENGINEER, 2005, 158 (02) :137-143
[5]  
Bhangar S, 2006, HLTH ENV DEV
[6]   Emission factors of wood and charcoal-fired cookstoves [J].
Bhattacharya, SC ;
Albina, DO ;
Salam, PA .
BIOMASS & BIOENERGY, 2002, 23 (06) :453-469
[7]  
Cohen J, APPL MULTIPLE REGRES
[8]  
Dasgupta S., 2004, World Bank Policy Research Working Paper 3393
[9]  
Li Z, 2011, ENV INT
[10]   Woodsmoke health effects: A review [J].
Naeher, Luke P. ;
Brauer, Michael ;
Lipsett, Michael ;
Zelikoff, Judith T. ;
Simpson, Christopher D. ;
Koenig, Jane Q. ;
Smith, Kirk R. .
INHALATION TOXICOLOGY, 2007, 19 (01) :67-106