Effects on perceived air quality and symptoms of exposure to microbially produced metabolites and compounds emitted from damp building materials

被引:29
作者
Claeson, A. -S. [2 ]
Nordin, S. [1 ,3 ]
Sunesson, A. -L. [2 ]
机构
[1] Umea Univ, Dept Psychol, S-90187 Umea, Sweden
[2] Natl Inst Working Life, Umea, Sweden
[3] Orebro Univ Hosp, Dept Occupat & Environm Med, Orebro, Sweden
关键词
Perceived air quality; Health effects; VOCs; Mold; Building materials; Exposure studies; VOLATILE ORGANIC-COMPOUNDS; OZONE OXIDATION-PRODUCTS; INDOOR AIR; SENSORY IRRITATION; AIRBORNE CHEMICALS; SYNTHETIC MEDIA; HEALTH-RISK; ODOR; MIXTURE; NASAL;
D O I
10.1111/j.1600-0668.2008.00566.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work investigated perceived air quality and health effects from exposure to low to high levels of volatile organic compounds (VOCs) emitted from damp building materials and a mixture of molds growing on the materials. A mixture of Wallemia sebi, Fusarium culmorum, Penicillium chrysogenum, Ulocladium botrytis, and Aspergillus versicolor was inoculated on pine wood and particle board. In Study 1, each of 27 participants took part in two exposure conditions, one with air from molds growing on building materials (low levels of emissions from the building materials and the mold mixture) and one with blank air, both conditions during 60 min. In Study 2, each of 24 participants was exposed (10 min) four times in a 2 x 2 design randomly to air from moldy building materials (high levels) and blank, with and without nose-clip. The participants rated air quality and symptoms before, during, and after each exposure. Self-reported tear-film break-up time and attention and processing speed (Study 1) was also measured. Exposure to high VOC levels increased the reports of perceived poor air quality, and in the condition without nose-clip enhanced skin symptoms were also noted. No such outcome was observed when exposing the participants to low VOC levels.Emissions from building materials caused by dampness and microbial growth may be involved in indoor air health problems. This study showed that exposure to high levels of VOC emitted from damp building materials and a mixture of mold may cause perceived poor air quality. It also indicated that stimulation of chemical warning systems (the nasal chemosensory part of the trigeminal system and the olfactory system) may enhance skin symptoms.
引用
收藏
页码:102 / 112
页数:11
相关论文
共 56 条
[1]  
*ARB, 2000, HYG GRANSV ATG MOT L
[2]  
Borg G., 2001, PSYCHOLOGICA-COIMBRA, V28, P15
[3]   Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effects [J].
Bornehag, CG ;
Sundell, J ;
Bonini, S ;
Custovic, A ;
Malmberg, P ;
Skerfving, S ;
Sigsgaard, T ;
Verhoeff, A .
INDOOR AIR, 2004, 14 (04) :243-257
[4]   Why do women suffer from sick building syndrome more often than men? Subjective higher sensitivity versus objective causes [J].
Brasche, S ;
Bullinger, M ;
Morfeld, M ;
Gebhardt, HJ ;
Bischof, W .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (04) :217-222
[5]  
Brown S.K., 1999, ORGANIC INDOOR AIR P, P171
[6]   Volatile organic compounds (VOCs) emitted from materials collected from buildings affected by microorganisms [J].
Claeson, A. -S. ;
Sandstrom, M. ;
Sunesson, A. -L .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (03) :240-245
[7]   Identification using versatile sampling and analytical methods of volatile compounds from Streptomyces albidoflavus grown on four humid building materials and one synthetic medium [J].
Claeson, AS ;
Sunesson, AL .
INDOOR AIR, 2005, 15 :41-47
[8]   Volatile metabolites from microorganisms grown on humid building materials and synthetic media [J].
Claeson, AS ;
Levin, JO ;
Blomquist, G ;
Sunesson, AL .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (05) :667-672
[9]   Determinants for nasal trigeminal detection of volatile organic compounds [J].
Cometto-Muñiz, JE ;
Cain, WS ;
Abraham, MH .
CHEMICAL SENSES, 2005, 30 (08) :627-642
[10]   Detection of single and mixed VOCs by smell and by sensory irritation [J].
Cometto-Muñiz, JE ;
Cain, WS ;
Abraham, MH .
INDOOR AIR, 2004, 14 :108-117