Electrochemical behavior and determination of rutin on a pyridinium-based ionic liquid modified carbon paste electrode

被引:88
|
作者
Sun, Wei [1 ]
Yang, Maoxia [1 ]
Li, Yinzhuo [1 ]
Jiang, Qiang [1 ]
Liu, Shufeng [1 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Ecochem Engn, Qingdao 266042, Peoples R China
基金
美国国家科学基金会;
关键词
Ionic liquid; Carbon paste electrode; Rutin; Cyclic voltammetry; Electrochemistry;
D O I
10.1016/j.jpba.2008.09.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper the electrochemical behavior of rutin on a pyridinium-typed ionic liquid modified carbon paste electrode (IL-CPE) was investigated and further used for rutin sample determination. The IL-CPE showed strong electrocatalytic effects to the oxidation of rutin. In phosphate buffer solution (PBS, pH 2.5; 0.1 M) a pair of well-defined cyclic voltammetric redox peaks of rutin appeared with the redox peak located at 512 mV (Epa) and 448 mV (Epc) (vs. SCE), respectively. The redox peak current was increased about 27.5 times more than that on traditional carbon paste electrode (CPE). The electrochemical parameters of rutin on the IL-CPE were calculated with the results of the charge transfer coefficient (alpha), the number of electron transfer (n) and the electrode reaction rate constant (k(s)) as 0.53, 1.80 and 2.39 s(-1), respectively. The cathodic peak currents increased linearly with the concentration of rutin in the range from 5.0 x 10(-7) to 1.0 x 10(-4) M with the detection limit as 3.58 x 10(-7) M (3 alpha). The relative standard deviation (RSD) of 10 successive detection of 5.0 x 10(-5) M rutin was 4.2%. The method was successfully applied to the determination of rutin content in tablets samples with good recovery. The modified electrode showed good stability and reproducibility without the influence of the coexisting substances. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1326 / 1331
页数:6
相关论文
共 50 条
  • [1] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    TALANTA, 2008, 77 (01) : 325 - 330
  • [2] Electrochemical behavior of labetalol at an ionic liquid-modified carbon paste electrode and its electrochemical determination
    Zhang, Yan-Mei
    Duan, Cheng-Qian
    Gao, Zuo-Ning
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (02) : 281 - 294
  • [3] Electrochemical Behavior and Electrochemical Determination of Tiamulin Fumarate at an Ionic Liquid Modified Carbon Paste Electrode
    Liu, Li-Hong
    Duan, Cheng-Qian
    Gao, Zuo-Ning
    CROATICA CHEMICA ACTA, 2010, 83 (04) : 409 - 414
  • [4] Application of poly(acridine orange) and graphene modified carbon/ionic liquid paste electrode for the sensitive electrochemical detection of rutin
    Sun, Wei
    Wang, Yuhua
    Gong, Shixing
    Cheng, Yong
    Shi, Fan
    Sun, Zhenfan
    ELECTROCHIMICA ACTA, 2013, 109 : 298 - 304
  • [5] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [6] Detection of rutin at DNA modified carbon paste electrode based on a mixture of ionic liquid and paraffin oil as a binder
    Yan Wang
    Huayu Xiong
    Xiuhua Zhang
    Shengfu Wang
    Microchimica Acta, 2010, 170 : 27 - 32
  • [7] Detection of rutin at DNA modified carbon paste electrode based on a mixture of ionic liquid and paraffin oil as a binder
    Wang, Yan
    Xiong, Huayu
    Zhang, Xiuhua
    Wang, Shengfu
    MICROCHIMICA ACTA, 2010, 170 (1-2) : 27 - 32
  • [8] Electrochemical Behavior and Determination of Rutin on Modified Carbon Paste Electrodes
    Macikova, Pavla
    Halouzka, Vladimir
    Hrbac, Jan
    Bartak, Petr
    Skopalova, Jana
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [9] Electrochemical detection of rutin with a carbon ionic liquid electrode modified by Nafion, graphene oxide and ionic liquid composite
    Hu, Song
    Zhu, Huanhuan
    Liu, Shengyun
    Xiang, Jun
    Sun, Wei
    Zhang, Liqi
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 211 - 219
  • [10] Electrochemical detection of rutin with a carbon ionic liquid electrode modified by Nafion, graphene oxide and ionic liquid composite
    Song Hu
    Huanhuan Zhu
    Shengyun Liu
    Jun Xiang
    Wei Sun
    Liqi Zhang
    Microchimica Acta, 2012, 178 : 211 - 219