Light-intensity activities are important for estimating physical activity energy expenditure using uniaxial and triaxial accelerometers
被引:90
|
作者:
论文数: 引用数:
h-index:
机构:
Yamada, Yosuke
[1
]
论文数: 引用数:
h-index:
机构:
Yokoyama, Keiichi
[1
]
论文数: 引用数:
h-index:
机构:
Noriyasu, Risa
[1
]
论文数: 引用数:
h-index:
机构:
Osaki, Tomoaki
[1
]
论文数: 引用数:
h-index:
机构:
Adachi, Tetsuji
[2
]
Itoi, Aya
论文数: 0引用数: 0
h-index: 0
机构:
Kobe Womens Jr Coll, Dept Human Life Studies, Kobe, Hyogo, JapanKyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
Itoi, Aya
[3
]
Naito, Yoshihiko
论文数: 0引用数: 0
h-index: 0
机构:
Mukogawa Womens Univ, Sch Human Environm Sci, Dept Food Sci & Nutr, Nishinomiya, Hyogo, JapanKyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
Naito, Yoshihiko
[4
]
Morimoto, Taketoshi
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Prefectural Univ Med, Kyoto, JapanKyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
Morimoto, Taketoshi
[5
]
Kimura, Misaka
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Prefectural Univ Med, Kyoto, JapanKyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
Kimura, Misaka
[5
]
Oda, Shingo
论文数: 0引用数: 0
h-index: 0
机构:
Kyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, JapanKyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
Oda, Shingo
[1
]
机构:
[1] Kyoto Univ, Grad Sch Human & Environm Studies, Lab Sports Sci & Human Motor Control, Sakyo Ku, Kyoto 6068501, Japan
[2] Kyoto Interdisciplinary Inst Community Med, Dept Med & Sport Sci, Kyoto, Japan
[3] Kobe Womens Jr Coll, Dept Human Life Studies, Kobe, Hyogo, Japan
[4] Mukogawa Womens Univ, Sch Human Environm Sci, Dept Food Sci & Nutr, Nishinomiya, Hyogo, Japan
This study evaluated the validity of the total energy expenditure (TEE) estimated using uniaxial (ACCuni) and triaxial (ACCtri) accelerometers in the elderly. Thirty-two healthy elderly (64-87 years) participated in this study. TEE was measured using the doubly labeled water (DLW) method (TEEDLW). TEEACCuni (6.79 +/- A 1.08 MJ day(-1)) was significantly lower than TEEDLW (7.85 +/- A 1.54 MJ day(-1)) and showed wider limits of agreement (-3.15 to 1.12 MJ day(-1)) with a smaller correlation coefficient (r = 0.703). TEEACCtri (7.88 +/- A 1.27 MJ day(-1)) did not differ from TEEDLW and showed narrower limits of agreement (-1.64 to 1.72 MJ day(-1)) with a larger correlation coefficient (r = 0.835, P < 0.001). The estimated intensities of light activities were significantly lower with ACCuni. Greater mediolateral acceleration was observed during 6-min walk tests. The results suggest that ACCtri is a better choice than ACCuni for assessing TEE in the elderly.