Direct comparison of capillary electrophoresis and capillary liquid chromatography hyphenated to collision-cell inductively coupled plasma mass spectrometry for the investigation of Cd-, Cu- and Zn-containing metalloproteins

被引:53
作者
Montes-Bayon, M
Pröfrock, D
Sanz-Medel, A
Prange, A
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] GKSS Forschungszentrum Geesthacht GmbH, Inst Coastal Res, Operat Syst, D-21502 Geesthacht, Germany
[3] Univ Luneburg, Inst Environm Chem, FB Environm Sci 4, D-21335 Luneburg, Germany
关键词
CE; cLC; collision cell-reaction cell ICP-MS; metalloproteins;
D O I
10.1016/j.chroma.2006.02.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary liquid chromatography (cLC) and capillary electrophoresis (CE) have been critically compared for the separation of metalloproteins when using collision-cell inductively coupled plasma mass spectrometry (ICP-CC-MS) as detection system. For cLC separation, the selected column was a C-8 (0.3 mm I.D.) and the separation conditions involved a gradient up to 80% methanol in 10 mM ammonium acetate buffer (pH 7.4). The low flow rate used (3 mu L min(-1)) permitted the utilization of a high methanol content maintaining the sensitivity along the whole chromatographic run. For this purpose, a new low-flow interface has been developed based on a total consumption nebulizer. Similarly, CE has been studied as separation technique using a 75 mu m I.D. fused silica capillary and a running buffer of 20 mM Tris-HNO3 (pH 7.4) and working at 30 W Metallothionein (mixture of MT-I and -II) and superoxide dismutase (SOD) have been used as protein models in order to evaluate the separation/detection capabilities using the same injection volumes in both systems (20 nL). For both hybrid systems, separation parameters such as retention factor, numbers of theoretical plates, tailing factor and resolution have been critically compared. Also, the analytical performance characteristics of both hybrid systems have been evaluated and tested by analyzing the Cu-, Zn-species present in red blood cell extracts in order to explore more adequate separation methodology for the analysis of metalloproteins in complex matrices. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 144
页数:7
相关论文
共 23 条
[1]  
Allan AK, 2000, BRIT J NUTR, V84, P747
[2]   Metallothionein isoforms separation and cadmium speciation by capillary electrophoresis with ultraviolet and quadrupole-inductively coupled plasma mass spectrometric detection [J].
Alvarez-Llamas, G ;
de la Campa, MRF ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :105-119
[3]   ICP-MS for specific detection in capillary electrophoresis [J].
Alvarez-Llamas, G ;
de laCampa, MD ;
Sanz-Medel, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (01) :28-36
[4]   Sample stacking capillary electrophoresis with ICP-(Q) MS detection for Cd, Cu and Zn speciation in fish liver metallothioneins [J].
Alvarez-Llamas, G ;
de la Campa, MDF ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :460-466
[5]   Recent advances in capillary separations for proteomics [J].
Cooper, JW ;
Wang, YJ ;
Lee, CS .
ELECTROPHORESIS, 2004, 25 (23-24) :3913-3926
[6]  
DELCASTILLOBUST.E, 2005, ANAL CHEM, V77, P5615
[7]   Identification of water-soluble selenium-containing proteins in selenized yeast by size-exclusion-reversed-phase HPLC/ICPMS followed by MALDI-TOF and electrospray Q-TOF mass spectrometry [J].
Encinar, JR ;
Ouerdane, L ;
Buchmann, W ;
Tortajada, J ;
Lobinski, R ;
Szpunar, J .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3765-3774
[8]   Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Jensen, PK ;
Pasa-Tolic, L ;
Anderson, GA ;
Horner, JA ;
Lipton, MS ;
Bruce, JE ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2076-2084
[9]   Immunological impact of metals in harbor seals (Phoca vitulina) of the North Sea [J].
Kakuschke, A ;
Valentine-Thon, E ;
Griesel, S ;
Fonfara, S ;
Siebert, U ;
Prange, A .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (19) :7568-7575
[10]  
Leong FTL, 2003, ASIAN J SOC PSYCHOL, V6, P1