False air-bone gaps at 4 kHz in listeners with normal hearing and sensorineural hearing loss

被引:35
作者
Margolis, Robert H. [1 ,2 ]
Eikelboom, Robert H. [3 ,4 ,5 ]
Johnson, Chad [1 ]
Ginter, Samantha M. [1 ]
Swanepoel, De Wet [3 ,4 ,5 ]
Moore, Brian C. J. [6 ]
机构
[1] Univ Minnesota, Dept Otolaryngol, Minneapolis, MN 55455 USA
[2] Audiol Inc, Arden Hills, MN USA
[3] Ear Sci Inst, Subiaco, WA, Australia
[4] Univ Pretoria, Dept Commun Pathol, ZA-0002 Pretoria, South Africa
[5] Univ Western Australia, Sch Surg, Ear Sci Ctr, Nedlands, WA 6009, Australia
[6] Univ Cambridge, Dept Expt Psychol, Cambridge CB2 3EB, England
关键词
Audiometry; automated audiometry; hearing; hearing test; air conduction; bone conduction; threshold; air-bone gap; artificial mastoid; AMTAS(R) AUTOMATED-METHOD; CONDUCTION THRESHOLDS; ACOUSTIC RADIATION; VIBRATORS; CALIBRATION; VALIDATION; EAR;
D O I
10.3109/14992027.2013.792437
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: This report presents data from four studies to examine standard bone-conduction reference equivalent threshold force levels (RETFL), especially at 4 kHz where anomalous air-bone gaps are common. Design: Data were mined from studies that obtained air-and bone-conduction thresholds from normal-hearing and sensorineural hearing loss (SNHL) participants, using commercial audiometers and standard audiometric transducers. Study sample: There were 249 normal-hearing and 188 SNHL participants. Results: (1) Normal-hearing participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (-1.7 to 0.3 dB) and larger air-bone gaps at 4 kHz (10.6 dB). (2) SNHL participants had small air-bone gaps at 0.5, 1.0, and 2.0 kHz (-0.7 to 1.7 dB) and a larger air-bone gap at 4 kHz (14.1 dB). (3) The 4-kHz air-bone gap grew with air-conduction threshold from 10.1 dB when the air-conduction threshold was 5-10 dB HL to 21.1 dB when the air-conduction threshold was greater than 60 dB. (4) With the 4-kHz RETFL corrected by the average SNHL air-bone gap, the relationship between RETFL and frequency is linear with a slope of -12 dB per octave. Conclusions: The 4-kHz air-bone gaps for listeners with SNHL could be avoided by adjusting the 4-kHz RETFL by -14.1 dB.
引用
收藏
页码:526 / 532
页数:7
相关论文
共 31 条
[1]  
American National Standards Institute, 2010, SPEC AUD
[2]  
[Anonymous], 2017, ISO 389-1: Acoustics-Reference Zero for the Calibration of Audiometric Equipment
[3]  
[Anonymous], 1972, 3131972 ANSI
[4]  
[Anonymous], 1994, 3893 ISO
[5]  
ANSI, 1996, S361996 ANSI
[6]  
Bell I, 1980, Br J Audiol, V14, P73, DOI 10.3109/03005368009078905
[7]   BONE CONDUCTION CALIBRATION - CURRENT STATUS [J].
DIRKS, DD ;
LYBARGER, SF ;
OLSEN, WO ;
BILLINGS, BL .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1979, 44 (02) :143-155
[8]   BONE-VIBRATOR MEASUREMENTS - PHYSICAL CHARACTERISTICS AND BEHAVIORAL THRESHOLDS [J].
DIRKS, DD ;
KAMM, C .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1975, 18 (02) :242-260
[9]   Clinical validation of the AMTAS automated audiometer [J].
Eikelboom, Robert H. | ;
Swanepoel, De Wet ;
Motakef, Shahpar ;
Upson, Gemma S. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (05) :342-349
[10]   Age effects in the human middle ear: Wideband acoustical measures [J].
Feeney, MP ;
Sanford, CA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (06) :3546-3558