Simplified contrast ultrasound accurately reveals muscle perfusion deficits and reflects collateralization in PAD

被引:47
作者
Duerschmied, Daniel [1 ]
Zhou, Qian [1 ]
Rink, Elisabeth [1 ]
Harder, Dorothee [1 ]
Freund, Gabriele [1 ]
Olschewski, Manfred [2 ]
Bode, Christoph [1 ]
Hehrlein, Christoph [1 ]
机构
[1] Univ Hosp Freiburg, Dept Cardiol & Angiol, D-79106 Freiburg, Germany
[2] Univ Hosp Freiburg, Dept Med Biometry & Stat, D-79106 Freiburg, Germany
关键词
Contrast ultrasound; Muscle perfusion; Peripheral arterial disease; Collateralization; Diagnostic accuracy; PERIPHERAL-ARTERIAL-DISEASE; MYOCARDIAL BLOOD-FLOW; HUMAN SKELETAL-MUSCLE; ENHANCED ULTRASONOGRAPHY; CONTINUOUS-INFUSION; LOWER-EXTREMITIES; EXERCISE; PRESSURE; MODEL; US;
D O I
10.1016/j.atherosclerosis.2008.05.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Simplified contrast-enhanced ultrasound (CEUS) can be used to evaluate muscle perfusion in peripheral arterial disease (PAD). Here, we report its diagnostic accuracy for detecting symptomatic PAD. Additionally, we hypothesize that the extent of collateral formation is reflected by CEUS. Methods: Ultrasound contrast agent was injected into an antecubital vein of 58 control subjects and 52 symptomatic PAD patients and its appearance in the calf muscle was evaluated. Interreader variability was tested using 118 raw data films. Arterial collateralization of PAD patients was assessed by angiographic imaging. Results: PAD patients showed a significantly longer median time to peak intensity (TTP, 36.9s) than control subjects (19.4 s, p < 0.001) with longer TTPs in advanced PAD stages. The area under the receiver operating characteristic curve was 0.942 and the mean TTP difference between two blinded readers was 0.28 s. A TTP cut off at 30.5 s was associated with 91 % positive predictive value. PAD patients with good collateralization showed a significantly shorter TTP (34.1 s) than patients with poor collateralization (44.0s, p=0.008) but not a higher ankle-brachial index (ABI). Conclusions: CEUS accurately displays perfusion deficits of the calf muscle in symptomatic PAD patients. The degree of arterial collateralization is reflected by CEUS and not by ABI. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 30 条
[1]   Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine [J].
Bekeredjian, R ;
Grayburn, PA ;
Shohet, RV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) :329-335
[2]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
CLINICAL CHEMISTRY, 2003, 49 (01) :1-6
[4]   Detection of peripheral vascular stenosis by assessing skeletal muscle flow reserve [J].
Bragadeesh, T ;
Sari, I ;
Pascotto, M ;
Micari, A ;
Kaul, S ;
Lindner, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (05) :780-785
[5]   Invasive and non-invasive evaluation of spontaneous arteriogenesis in a novel porcine model for peripheral arterial obstructive disease [J].
Buschmann, IR ;
Voskuil, M ;
van Royen, N ;
Hoefer, IE ;
Scheffler, K ;
Grundmann, S ;
Hennig, J ;
Schaper, W ;
Bode, C ;
Piek, JJ .
ATHEROSCLEROSIS, 2003, 167 (01) :33-43
[6]  
Delorme Stefan, 2006, Cancer Imaging, V6, P148, DOI 10.1102/1470-7330.2006.0023
[7]   High prevalence of peripheral arterial disease and co-morbidity in 6880 primary care patients: cross-sectional study [J].
Diehm, C ;
Schuster, A ;
Allenberg, JR ;
Darius, H ;
Haberl, R ;
Lange, S ;
Pittrow, D ;
von Stritzky, B ;
Tepohl, G ;
Trampisch, HJ .
ATHEROSCLEROSIS, 2004, 172 (01) :95-105
[8]   Contrast ultrasound perfusion imaging of lower extremities in peripheral arterial disease: a novel diagnostic method [J].
Duerschmied, D ;
Olson, L ;
Olschewski, M ;
Rossknecht, A ;
Freund, G ;
Bode, C ;
Hehrlein, C .
EUROPEAN HEART JOURNAL, 2006, 27 (03) :310-315
[9]  
Frank LR, 1999, MAGN RESON MED, V42, P258, DOI 10.1002/(SICI)1522-2594(199908)42:2<258::AID-MRM7>3.0.CO
[10]  
2-E