T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision

被引:136
|
作者
Kellman, Peter [1 ]
Arai, Andrew E. [1 ]
Xue, Hui [1 ]
机构
[1] Natl Heart Lung & Blood Inst, Natl Inst Hlth, DHHS, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
T1; Map; Error; Precision; MOLLI; Extracellular; Diffuse Fibrosis; Cardiovascular Magnetic Resonance; SENSITIVE INVERSION-RECOVERY; DIFFUSE MYOCARDIAL FIBROSIS; MAGNETIC-RESONANCE; QUANTIFICATION; VALIDATION; INFARCTION; REGRESSION; MOLLI;
D O I
10.1186/1532-429X-15-56
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Quantitative measurements in the myocardium may be used to detect both focal and diffuse disease processes that result in an elevation of T1 and/or extracellular volume (ECV) fraction. Detection of abnormal myocardial tissue by these methods is affected by both the accuracy and precision. The sensitivity for detecting abnormal elevation of T1 and ECV is limited by the precision of T1 estimates which is a function of the number and timing of measurements along the T1-inversion recovery curve, the signal-to-noise ratio (SNR), the tissue T1, and the method of fitting. Methods: The standard deviation (SD) of T1 and ECV estimates are formulated and SD maps are calculated on a pixel-wise basis using the Modified Look-Locker Inversion recovery (MOLLI) method. SD estimates are validated by numerical simulation using Monte-Carlo analysis and with phantoms using repeated trials. SD estimates are provided for pre- and post-contrast optimized protocols for a range of T1s and SNRs. In-vivo examples are provide for normal, myocarditis, and HCM in human subjects. The formulation of SD maps was extended to R1 and ECV. Results: The measured myocardial SNR ranged from 23 to 43 across the heart using the specific T1-mapping protocol in this study. In this range of SNRs, the estimated SD for T1 was approximately 20-45 ms for pre-contrast myocardial T1 around 1000 ms, and was approximately 10-20 ms for post contrast T1 around 400 ms. The proposed estimate of SD was an unbiased estimate of the standard deviation of T1 validated by numerical simulation and had > 99% correlation with phantom measurements. The measured SD maps exhibited variation across the heart due to drop off in surface coil sensitivity as expected for the variation in SNR. Focal elevation in T1 and ECV was shown to have statistical significance on a pixel-wise basis for in-vivo examples. Conclusions: Pixel-wise estimates of T1 mapping errors have been formulated and validated, and the formulation has been extended to ECV. The ability to quantify the measurement error has potential to determine the statistical significance of subtle abnormalities that arise due to diffuse disease processes involving fibrosis and/or edema and is useful both as a confidence metric for overall quality, and in optimization and comparison of imaging protocols.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] REPLY: Effects of Blood T1 on Extracellular Volume Calculation
    White, Steven K.
    Treibel, Thomas A.
    Moon, James C.
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (08) : 849 - 850
  • [42] Extracellular volume imaging by T1 mapping cardiovascular magnetic resonance in patients with clinically suspected myocarditis
    Ulf K Radunski
    Gunnar Lund
    Mandana D Nariman
    Bernhard Schnackenburg
    Christian Stehning
    Gerhard Adam
    Stefan Blankenberg
    Kai Muellerleile
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [43] Modified look-locker inversion recovery (MOLLI) T1 mapping with inversion group (IG) fitting - A method for improved precision
    Sussman, Marshall S.
    Wintersperger, Bernd J.
    MAGNETIC RESONANCE IMAGING, 2019, 62 : 38 - 45
  • [44] Comprehensive cardiac magnetic resonance T1, T2, and extracellular volume mapping to define Duchenne cardiomyopathy
    Sunthankar, Sudeep D.
    George-Durrett, Kristen
    Crum, Kimberly
    Slaughter, James C.
    Kasten, Jennifer
    Raucci Jr, Frank J.
    Markham, Larry W.
    Soslow, Jonathan H.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [45] Extracellular volume fraction and native T1 mapping in diabetic cardiomyopathy: a comprehensive meta-analysis
    Marey, Ahmed
    Alabdullah, Ali
    Ghorab, Hossam
    Ali, Fatima
    Abdulla, Jawdat
    Narang, Akhil
    Umair, Muhammad
    BMC CARDIOVASCULAR DISORDERS, 2025, 25 (01):
  • [46] Optimized saturation recovery protocols for T1-mapping in the heart: influence of sampling strategies on precision
    Kellman, Peter
    Xue, Hui
    Chow, Kelvin
    Spottiswoode, Bruce S.
    Arai, Andrew E.
    Thompson, Richard B.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [47] Myocardial T1 and extracellular volume fraction measurement in asymptomatic patients with aortic stenosis: reproducibility and comparison with age-matched controls
    Singh, Anvesha
    Horsfield, Mark A.
    Bekele, Soliana
    Khan, Jamal N.
    Greiser, Andreas
    McCann, Gerry P.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (07) : 763 - 770
  • [48] Accelerated and Navigator-Gated Look-Locker Imaging for Cardiac T1 Estimation (ANGIE): Development and Application to T1 Mapping of the Right Ventricle
    Mehta, Bhairav B.
    Chen, Xiao
    Bilchick, Kenneth C.
    Salerno, Michael
    Epstein, Frederick H.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 150 - 160
  • [49] Increased myocardial native T1 and extracellular volume in patients with Duchenne muscular dystrophy
    Soslow, Jonathan H.
    Damon, Stephen M.
    Crum, Kimberly
    Lawson, Mark A.
    Slaughter, James C.
    Xu, Meng
    Arai, Andrew E.
    Sawyer, Douglas B.
    Parra, David A.
    Damon, Bruce M.
    Markham, Larry W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [50] Identification of myocardial diffuse fibrosis by 11 heartbeat MOLLI T1 mapping: averaging to improve precision and correlation with collagen volume fraction
    Vassilios S. Vassiliou
    Katharina Wassilew
    Donnie Cameron
    Ee Ling Heng
    Evangelia Nyktari
    George Asimakopoulos
    Anthony de Souza
    Shivraman Giri
    Iain Pierce
    Andrew Jabbour
    David Firmin
    Michael Frenneaux
    Peter Gatehouse
    Dudley J. Pennell
    Sanjay K. Prasad
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 101 - 113