Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs

被引:52
作者
Pathirana, Sameera Wijesiri [1 ]
Uy, Brian [1 ]
Mirza, Olivia [2 ]
Zhu, Xinqun [2 ]
机构
[1] Univ New S Wales, Ctr Infrastruct Engn & Safety, Kensington, NSW 2052, Australia
[2] Univ Western Sydney, Inst Infrastruct Engn, Penrith, NSW 2751, Australia
基金
澳大利亚研究理事会;
关键词
Bolted connectors; Composite beams; Damage parameters; Finite element modeling; Grout; Push-tests; Rigid plastic analysis; Retrofitting; Shear connectors; BEHAVIOR;
D O I
10.1016/j.jcsr.2015.09.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper considers the flexural behaviour of steel-concrete composite beams retrofitted with two types of bolted connectors and welded stud connectors. Three composite beams, one from each connector type, and four non-composite beams were cast together. Three of the non-composite beams were retrofitted using the three connector types respectively. The connectors were installed through holes cored in the concrete slabs of the beams. The holes were backfilled using structural grout. The beams were then tested under static flexural loading. The load-slip behaviour of these connectors under normal and retrofitted conditions was investigated using push-tests. The flexural behaviour of the retrofitted beams was compared with that of the normal composite beams and non-composite beams. The ultimate loads of the test specimens were compared with the design ultimate loads of these beams calculated using Rigid Plastic Analysis (RPA). The vertical deflection of the beams under serviceable load regimes was also compared. The beam experiments were simulated using Finite Element (FE) models developed with ABAQUS. Material models with damage parameters were specified for the concrete and grout used in the test specimens using the Concrete Damage Plasticity (CDP) option. The effects of the concrete and grout strength, grout-hole size and shear connection ratio on the flexural behaviour of retrofitted beams were investigated by carrying out a parametric analysis. The results obtained from full-scale beam and push-test experiments and also the analytical results from RPA and FE analyses are presented and discussed in detail in this paper. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:417 / 430
页数:14
相关论文
共 20 条
[1]  
ABAQUS, 2010, DOC VERS 6 10
[2]  
[Anonymous], 1992, 19941 DDENV
[3]  
CARREIRA DJ, 1985, J AM CONCRETE I, V82, P797
[4]  
Engineers Australia, AUSTR INFR REP CARD
[5]   Behavior of post-installed shear connectors under static and fatigue loading [J].
Kwon, Gunup ;
Engelhardt, Michael D. ;
Klingner, Richard E. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) :532-541
[6]  
Lam D., 2012, P 10 INT C ADV STEEL
[7]   Ultimate strength of continuous composite beams in combined bending and shear [J].
Liang, QQ ;
Uy, B ;
Bradford, MA ;
Ronagh, HR .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (08) :1109-1128
[8]  
Mirza O, 2010, ADV STEEL CONSTR, V6, P635
[9]   Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures [J].
Mirza, O. ;
Uy, B. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (03) :662-674
[10]  
Mirza O., 2010, 4 INT C STEEL COMP S