Passive control strategy for mixing ventilation in heating mode using lobed inserts

被引:11
作者
Braganca, Pierre [1 ]
Sodjavi, Kodjovi [1 ]
Meslem, Amina [2 ]
Nastase, Ilinca [3 ]
机构
[1] Univ La Rochelle, LaSIE, Pole Sci & Technol, Ave Michel Crepeau, F-17042 La Rochelle, France
[2] Univ Rennes 1, LGCGM EA3913, 3 Rue Clos Courtel,BP 90422, F-35704 Rennes 7, France
[3] Tech Univ Civil Engn Bucharest, Fac Bldg Serv Engn, CAMBI Res Ctr, Bucharest, Romania
关键词
Mixing ventilation; Ceiling diffuser; Heating mode; Lobed inserts; Lobed jet; Thermal comfort; PARTICLE IMAGE VELOCIMETRY; THERMAL COMFORT; AIR-DISTRIBUTION; ENTRAINMENT; FLOW; JET; TURBULENCE; DIFFUSION; FIELD;
D O I
10.1016/j.enbuild.2016.10.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The main purpose of ventilation systems is to satisfy the need of occupants in terms of thermal comfort and air quality. In the case of mixing ventilation, based on the use of jets from one or from multiple diffusers placed in the room, the fresh air and the thermal loads should be distributed in the entire occupied zone. Therefore, the design of the diffusers must aim, beyond aesthetic aspect, the ability to provide a good mixing between the jet and the ambient air. Enhancement of jet induction by means of lobed inserts into a diffuser, was recently proposed in an European patent as a promising and low-cost solution for improving the performance of HVAC systems. In this paper, an experimental investigation on jet characteristics and thermal comfort generated by a classical multi-cone ceiling-mounted diffuser is proposed. Its performance is compared with the same diffuser equipped with lobed inserts. A simplified heated manikin simulates the presence of a human body in the test room. Airflow pattern from the diffuser and its interaction with the manikin were analyzed with whole-field PIV technique. Thermal comfort was analyzed based on traditional pointwise measuring probes and on the standard ISO 7730. It is revealed that the thermal comfort was significantly improved using the lobed diffuser compared to the conventional one, without increase of pressure drop and sound pressure levels. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:512 / 528
页数:17
相关论文
共 48 条
[1]  
[Anonymous], ASME TURBO EXPO 2007
[2]  
[Anonymous], 2013, 55 ANSIASHRAE
[3]  
[Anonymous], HELATH BUILD 2003 P
[4]  
[Anonymous], HEAT AIR TECHN C
[5]  
[Anonymous], 1953, ASHVE T
[6]  
[Anonymous], ROMANIAN J CIV ENG
[7]  
[Anonymous], [No title captured]
[8]  
[Anonymous], 1996 ANN C SAN ANT T
[9]  
[Anonymous], 12238 AFNOR NF EN
[10]  
[Anonymous], ENG TURBUL MODEL EXP