OPTIMIZATION OF IMPLANT-ABUTMENT CONNECTION IN ELECTRO-WELDED IMPLANTOLOGY: STUDY AND MECHANICAL CHARACTERIZATION

被引:0
|
作者
Fanali, S. [1 ]
Villa, T. [2 ]
Fanali, D.
Carinci, F. [3 ]
机构
[1] Univ G dAnnunzio, Dept Oral Sci Nano & Biotechnol, Chieti, Italy
[2] IRCCS Ist Ortoped Galeazzi, Dept Struct, Milan, Italy
[3] Univ Ferrara, Dept DMCCC, Sect Maxillofacial Surg, I-44100 Ferrara, Italy
来源
EUROPEAN JOURNAL OF INFLAMMATION | 2011年 / 9卷 / 01期
关键词
abutment design; yield point; fatigue failure; mechanical complications; maximum load; one-pice abutment; two-piece abutment;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The aim of this study is to compare in vitro the mechanical resistance of 7 different implant-abutment connections and determine which of them has the best mechanical performances (both statically and when subjected to dynamic loads) and which of them can guarantee the best level of tenacity during the clinical use of the intraoral electro-welded implantology with the hi-phase implants. All the implants were machined by Falappa Medical Devices - Rome. Two types of tests have been performed: static tests and fatigue tests. The static tests were performed on four specimens for each typology of connection, the fatigue tests on three specimens for each typology of connection. Configuration followed ISO 14801 standard.. The static tests were performed until rupture while the fatigue tests were performed applying a 108-1080 N load until either break was detected or 5 Mcycles were reached. Results showed that good static behavior does not involve automatically that the connection has also good long-term performances. Statistically significant differences were noted among the configurations: in particular internal connectors showed better results in comparison to external ones and among internal connectors the hexagonal one turned out to be the best one even if almost all the connectors had sufficient resistance to withstand normal masticatory loads.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [1] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [2] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [3] Essay 3: Biologic and mechanical principals of the implant-abutment connection
    不详
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2011, 6 (02): : 246 - 251
  • [4] The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study
    Bagegni, Aimen
    Weihrauch, Vincent
    Vach, Kirstin
    Kohal, Ralf
    MATERIALS, 2022, 15 (09)
  • [5] Characterization of the microstructure and mechanical behavior of electro-welded wire meshes: A case study in Colombia
    Miranda-Giraldo, Michael
    Gonzalez-Olier, Camilo
    Zambrano, Habib R.
    Arteta, Carlos A.
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [6] Histology of a dental implant with a platform switched implant-abutment connection
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF OSSEOINTEGRATION, 2011, 3 (03) : 56 - 60
  • [7] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113
  • [8] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    Journal of the Mechanical Behavior of Biomedical Materials, 2021, 113
  • [9] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [10] Implant-Abutment Connection Deformation After Prosthetic Procedures: An In Vitro Study
    Micarelli, Costanza
    Canullo, Luigi
    Iannello, Giuliano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (03) : 282 - 286