Environmentally friendly disposable sensors with microfabricated on-chip planar bismuth electrode for in situ heavy metal ions measurement

被引:175
作者
Zou, Zhiwei [1 ]
Jang, Am [2 ]
MacKnight, Eric [1 ]
Wu, Pei-Ming [1 ]
Do, Jaephil [1 ]
Bishop, Paul L. [2 ]
Ahn, Chong H. [1 ]
机构
[1] Univ Cincinnati, Dept Elect & Comp Engn, MicroSyst & BioMEMS Lab, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Dept Civil & Environm Engn, Cincinnati, OH 45221 USA
关键词
Heavy metal ion; Bismuth electrode; Anodic stripping voltammetry; In situ measurement;
D O I
10.1016/j.snb.2008.04.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents an environmentally friendly disposable heavy metal ion sensor for in situ and online monitoring in the nature and physiological systems. The miniaturized sensor chip consists of a non-toxic microfabricated bismuth (Bi) working electrode that replaces the conventional mercury electrodes, an integrated Ag/AgCl reference electrode, a gold counter electrode, and microfluidic channels. In this work, the electrochemical behavior of the Bi working electrode was characterized in several non-deaerated buffer solutions using cyclic voltammetry. The detection and quantification of Pb (II) and Cd (II) were statically performed using anodic stripping voltammetry inside the microchannels. in the Pb (II) concentration range of 25-400 ppb (R-2 = 0.991) with limit of detection of 8 ppb for 60 s deposition, and in the Cd (II) concentration range of 28-280 ppb (R-2 = 0.986) with limit of detection of 9.3 ppb for 90 s deposition. Particularly, the applications of this sensor chip have been reported with the examples of in situ measurement of Cd (II) concentration in soil pore and ground water and online direct measurement of Cd (II) concentration in cell culture media in its native environment. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 49 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[3]   Determination of heavy metal ions based on quenching of the rare earth luminescence [J].
Arakawa, T ;
Muraki, A ;
Hashimoto, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :832-835
[4]   Anodic stripping voltammetry at bismuth-coated and uncoated carbon microdisk electrodes: Application to trace metals analysis in food samples [J].
Baldo, MA ;
Daniele, S .
ANALYTICAL LETTERS, 2004, 37 (05) :995-1011
[5]   Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2007, 599 (02) :249-255
[6]   Effect of Bi(III) concentration on the stripping voltammetric response of in situ bismuth-coated carbon paste and gold electrodes [J].
Baldrianova, L. ;
Svancara, I. ;
Vlcek, M. ;
Economou, A. ;
Sotiropoulos, S. .
ELECTROCHIMICA ACTA, 2006, 52 (02) :481-490
[7]   Anodic stripping voltammetry at in situ bismuth-plated carbon and gold microdisc electrodes in variable electrolyte content unstirred solutions [J].
Baldrianova, L. ;
Svancara, I. ;
Economou, A. ;
Sotiropoulos, S. .
ANALYTICA CHIMICA ACTA, 2006, 580 (01) :24-31
[8]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[9]  
Ben Ali M, 2000, SENSOR ACTUAT B-CHEM, V62, P233
[10]   Human prostate cancer risk factors [J].
Bostwick, DG ;
Burke, HB ;
Djakiew, D ;
Euling, S ;
Ho, SM ;
Landolph, J ;
Morrison, H ;
Sonawane, B ;
Shifflett, T ;
Waters, DJ ;
Timms, B .
CANCER, 2004, 101 (10) :2371-2490