Performance analysis and comparison of concentrated evacuated tube heat pipe solar collectors

被引:64
作者
Nkwetta, Dan Nchelatebe [1 ]
Smyth, Mervyn [2 ]
机构
[1] Tata Steel, Corus Colors, Sustainable Bldg Envelope Ctr, Deeside, Flint, Wales
[2] Univ Ulster, Fac Arts Design & Built Environm, Sch Built Environm, Ctr Sustainable Technol, Newtownabbey, North Ireland
关键词
Concentrated evacuated tube heat pipe; Single-sided coated absorber; Double-sided coated absorber and incident angle modifier; COOLING SYSTEM; DESIGN;
D O I
10.1016/j.apenergy.2012.02.059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two profiles of concentrated evacuated tube heat pipe solar collectors made of single-sided and double-sided absorber have been analyzed and compared under control conditions and results presented in this paper. These innovative concentrated evacuated tube heat pipe solar collectors were experimentally tested at a tilt angle of 60 degrees to the horizontal. Using in-door solar simulated experimental conditions temperature response, collection efficiency, heat loss coefficients and energy collection rates as well as the incident angle modifier (IAM) were recorded and compared at five different transverse angles (0-40 degrees) at 10 degrees increments. The use of concentrated single-sided and double-sided absorber evacuated tube heat pipe solar collectors is seen to be feasible for integrating solar thermal energy into buildings for heating demands. The concentrated double-sided absorber evacuated tube heat pipe proves better compared to the concentrated single-sided absorber evacuated tube heat pipe solar collector due to higher outlet temperature with greater temperature differential and improved thermal performance. The integration of this innovative system implies that the number of the evacuated tube heat pipe collectors needed to attain higher temperature is reduced. Furthermore, the size of reflectors and related reflector losses are reduced due to the truncated nature of the reflectors providing a low concentration ratio. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 25 条
[1]   Design and experimental testing of the performance of an outdoor LiBr/H2O solar thermal absorption cooling system with a cold store [J].
Agyenim, Francis ;
Knight, Ian ;
Rhodes, Michael .
SOLAR ENERGY, 2010, 84 (05) :735-744
[2]  
ANSI/ASHRAE Standard, 2009, THERM EV HEAT PIP SO
[3]   Active solar space heating of residential buildings in northern Hellas - a case study [J].
Argiriou, A ;
Klitsikas, N ;
Balaras, CA ;
Asimakopoulos, DN .
ENERGY AND BUILDINGS, 1997, 26 (02) :215-221
[4]   Design, optimisation and conversion-efficiency determination of a line-focus parabolic-trough solar-collector (PTC) [J].
Bakos, GC ;
Ioannidis, I ;
Tsagas, NF ;
Seftelis, I .
APPLIED ENERGY, 2001, 68 (01) :43-50
[5]   THERMAL PERFORMANCE OF A FLAT-PLATE HEAT-PIPE COLLECTOR ARRAY [J].
BONG, TY ;
NG, KC ;
BAO, H .
SOLAR ENERGY, 1993, 50 (06) :491-498
[6]  
Chi S.W., 1976, HEAT PIPE THEORY PRA
[7]  
Dan Nchelatebe N, 2003, HIGH TEMP PYR US MAN, p13th
[8]  
DAN NN, 2010, THESIS U ULSTER UK, DOI DOI 10.1016/J.SOLENER.2010.01.013
[9]  
DTI, 2003, EN WHIT PAP OUR EN F
[10]  
DUFFIE JA, 2006, SOLAR ENG THERMAL PR, DOI DOI 10.1016/J.ENCONMAN.2003.12.019