Significance of venous oximetry in the critically ill

被引:21
作者
Bauer, P. [1 ]
Reinhart, K. [1 ]
Bauer, M. [1 ]
机构
[1] Univ Jena, Dept Anaesthesiol & Crit Care Med, D-07740 Jena, Germany
关键词
oxygen; monitoring; critical illness;
D O I
10.1016/S0210-5691(08)70923-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Critically ill patients are threatened or affected by multi-organ failure (MOF). Tissue hypoxia is one of the most important co-factors of MOF. Venous oximetry allows the critical estimation of the global oxygen (O-2) supply-demand ratio and can be gained from mixed (SvO2) and central venous blood (ScvO2). Cellular requirements dominate the feedback hierarchy of the O-2-metabolism. This review describes the history and validity of haemodynamic monitoring, illustrates the physiological background and clinical application of venous oxymetry and presents carbon dioxide analysis as evidence of the usefulness of a multi-modal approach in cardio-respiratory monitoring. Variation of cardiac output, optimisation of arterial O-2-saturation and adaptation of O-2-extraction are shown to be the relevant levels of pathophysiological adaptation as well as therapeutic intervention. We portray the functional equivalence of ScvO2 and SvO2 and analyse their diagnostic, therapeutic and prognostic significance, providing the basis for the efficacy of venous oximetry as an important marker of critical illness. Finally, having drawn an outline of current developments for the better understanding of the oxidative balance of individual organs, we stress the importance of a synoptic O-2-monitoring strategy as well as the need to use its beneficial, yet unfulfilled, clinical potential.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 23 条
[1]  
BAUER P, 2007, INT J INTENSIVE CARE, V14, P19
[2]  
Carlet J, 1996, AM J RESP CRIT CARE, V154, P1573
[3]   Lack of equivalence between central and mixed venous oxygen saturation [J].
Chawla, LS ;
Zia, H ;
Gutierrez, G ;
Katz, NM ;
Seneff, MG ;
Shah, M .
CHEST, 2004, 126 (06) :1891-1896
[4]   Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock [J].
Dellinger, RP ;
Carlet, JM ;
Masur, H ;
Gerlach, H ;
Calandra, T ;
Cohen, J ;
Gea-Banacloche, J ;
Keh, D ;
Marshall, JC ;
Parker, MM ;
Ramsay, G ;
Zimmerman, JL ;
Vincent, JL ;
Levy, MM .
CRITICAL CARE MEDICINE, 2004, 32 (03) :858-873
[5]   Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia [J].
Dubin, A ;
Murias, G ;
Estenssoro, E ;
Canales, H ;
Badie, J ;
Pozo, M ;
Sottile, JP ;
Barán, M ;
Pálizas, F ;
Laporte, M .
CRITICAL CARE, 2002, 6 (06) :514-520
[6]   Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions [J].
Dueck, MH ;
Klimek, M ;
Appenrodt, S ;
Weigand, C ;
Boerner, U .
ANESTHESIOLOGY, 2005, 103 (02) :249-257
[7]  
FICK A, 1870, SITZUNGSBERICHT PHYS, V2, pR16
[8]   Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial [J].
Harvey, S ;
Harrison, DA ;
Singer, M ;
Ashcroft, J ;
Jones, CM ;
Elbourne, D ;
Brampton, W ;
Williams, D ;
Young, D ;
Rowan, K .
LANCET, 2005, 366 (9484) :472-477
[9]   Circulatory questions [J].
Jarisch, A .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1928, 54 :1211-1213
[10]   Meta-analysis of hemodynamic optimization in high-risk patients [J].
Kern, JW ;
Shoemaker, WC .
CRITICAL CARE MEDICINE, 2002, 30 (08) :1686-1692