A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip

被引:46
作者
Balakrishnan, S. R. [1 ]
Hashim, U. [1 ]
Gopinath, Subash C. B. [1 ]
Poopalan, P. [2 ]
Ramayya, H. R. [3 ]
Omar, M. Iqbal [4 ]
Haarindraprasad, R. [1 ]
Veeradasan, P. [1 ]
机构
[1] Univ Malaysia Perlis, Inst Nano Elect Engn INEE, Biomed Nano Diagnost Res Grp, Kangar, Perlis, Malaysia
[2] Univ Malaysia Perlis, Sch Microelect Engn, Kuala Perlis, Perlis, Malaysia
[3] Hosp Tuanku Fauziah, Dept Obstet & Gynaecol, Kangar, Perlis, Malaysia
[4] Univ Malaysia Perlis, Univ Hlth Ctr, Kuala Perlis, Perlis, Malaysia
关键词
SENSITIVE DETECTION; BETA-HCG; AMPEROMETRIC IMMUNOSENSOR; PROTEIN ADSORPTION; MICROPIPETTE TIP; CARBON NANOTUBES; PHOTOMASK DESIGN; HIGH-THROUGHPUT; BIOSENSOR; IMMUNOASSAY;
D O I
10.1371/journal.pone.0137891
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 x 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl) triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 mu A mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant K-d of the specific antigen binding to the anti-hCG was calculated as 2.23 +/- 0.66 mIU, and the maximum number of binding sites per antigen was B-max = 22.54 +/- 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets.
引用
收藏
页数:17
相关论文
共 69 条
[1]  
[Anonymous], 2012, INT J ENHANCED RES S
[2]  
Azimi P, 2011, AFRICAN REV PHYS, P4
[3]   Development of highly sensitive polysilicon nanogap with APTES/GOx based lab-on-chip biosensor to determine low levels of salivary glucose [J].
Balakrishnan, Sharma Rao ;
Hashim, U. ;
Letchumanan, G. R. ;
Kashif, M. ;
Ruslinda, A. R. ;
Liu, W. W. ;
Veeradasan, P. ;
Prasad, R. Haarindra ;
Foo, K. L. ;
Poopalan, P. .
SENSORS AND ACTUATORS A-PHYSICAL, 2014, 220 :101-111
[4]   The role of carboxy-terminal portion of beta subunit of human chorionic gonadotropin in human immunodeficiency virus infection [J].
Bourinbaiar, AS ;
Powell, JE ;
Stevens, VC .
LIFE SCIENCES, 1997, 61 (11) :PL149-PL157
[5]   Analytical and clinical validation of the Immulite 1000 hCG assay for quantitative analysis in urine [J].
Cate, Frances L. ;
Moffett, Courtney ;
Gronowski, Ann M. ;
Grenache, David G. ;
Hartmann, Katherine E. ;
Woodworth, Alison .
CLINICA CHIMICA ACTA, 2013, 421 :104-108
[6]   Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin [J].
Chai, Rong ;
Yuan, Ruo ;
Chai, Yaqin ;
Ou, Chaofeng ;
Cao, Shurui ;
Li, Xuelian .
TALANTA, 2008, 74 (05) :1330-1336
[7]   Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase [J].
Chen, J ;
Yan, F ;
Dai, Z ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :330-336
[8]  
Cole LA, 2012, REPROD BIOL ENDOCRIN, P10
[9]   New discoveries on the biology and detection of human chorionic gonadotropin [J].
Cole, Laurence A. .
REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2009, 7
[10]   Qualitative β-hCG urine assays may be misleading in the presence of molar pregnancy:: A case report [J].
Davison, CM ;
Kaplan, RM ;
Wenig, LN ;
Burmeister, D .
JOURNAL OF EMERGENCY MEDICINE, 2004, 27 (01) :43-47