Application of amperometric sol-gel biosensor to flow injection determination of glucose

被引:27
作者
Couto, CMCM
Araújo, AN
Montenegro, MCBSM
Rohwedder, J
Raimundo, I
Pasquini, C
机构
[1] CEQUP, Dept Quim Fis, Fac Farm, P-4050 Oporto, Portugal
[2] Univ Estadual Campinas, Inst Quim, Campinas, SP, Brazil
[3] Inst Super Ciencias Saude, P-4580 Gandra, Paredes, Portugal
关键词
flow injection analysis; glucose oxidase; sol-gel; glucose biosensor;
D O I
10.1016/S0039-9140(01)00587-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose biosensor with enzyme immobilised by sol-gel technology was constructed and evaluated. The glucose biosensor reported is based on encapsulated GOX within a sol-gel glass, prepared with 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)-ethyltrimetoxy silane and HCl. A flow system incorporating the amperometric biosensor constructed was developed for the determination of glucose in the 1 x 10(-4)-5 x 10(-3) mol 1(-1) range with a precision of 1.5%. The results obtained for the analysis of electrolytic solution for iv administration and human serum samples showed good agreement between the proposed method and the reference procedure, with relative error < 5%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:997 / 1003
页数:7
相关论文
共 24 条
[1]   ELECTROCHEMICAL PROBING OF THE ACTIVITY OF GLUCOSE-OXIDASE EMBEDDED SOL-GEL MATRICES [J].
AUDEBERT, P ;
DEMAILLE, C ;
SANCHEZ, C .
CHEMISTRY OF MATERIALS, 1993, 5 (07) :911-913
[2]   THE SOL-GEL PREPARATION OF SILICA-GELS [J].
BUCKLEY, AM ;
GREENBLATT, M .
JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (07) :599-602
[3]   SOL-GEL VANADIUM PENTAOXIDE GLUCOSE BIOSENSOR [J].
GLEZER, V ;
LEV, O .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (06) :2533-2534
[4]   IMMOBILIZED ENZYMES IN ANALYTICAL-CHEMISTRY [J].
GRAY, DN ;
KEYES, MH ;
WATSON, B .
ANALYTICAL CHEMISTRY, 1977, 49 (12) :1067-&
[5]   Screen-printable surfactant-induced sol-gel graphite composites for electrochemical sensors [J].
Guo, YZ ;
Guadalupe, AR .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) :213-219
[6]  
KUNNZELMANN U, 1997, SENSOR ACTUAT B-CHEM, V38, P222
[7]  
LEV O, 1992, ANALUSIS, V20, P543
[8]   Mediated amperometric glucose sensor modified by the sol-gel method [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN ;
Ge, H .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) :135-141
[9]   Optimization and characterization of a flow injection electrochemical system for pentachlorophenol assay [J].
Male, KB ;
Saby, C ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4134-4139
[10]   GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM [J].
NARANG, U ;
PRASAD, PN ;
BRIGHT, FV ;
RAMANATHAN, K ;
KUMAR, ND ;
MALHOTRA, BD ;
KAMALASANAN, MN ;
CHANDRA, S .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3139-3144