Determination of Free Glycerol in Biodiesel by Molecularly Imprinted Polymer - Based Solid-Phase Extraction (SPE) Using an Enzymatic Spectrophotometric Assay

被引:4
作者
Moreira, Brayan Machado [1 ]
Cunha, Jessica Nogueira da [1 ]
Paiva, Victor Magno [1 ]
Honorio, Glaucio Gualtieri [1 ]
Tarley, Ricardo Teixeira [2 ,3 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Chem, BR-21941909 Rio De Janeiro, Brazil
[2] Univ Estadual Londrina, Inst Chem, Londrina, Parana, Brazil
[3] Univ Estadual Campinas, Inst Chem, Sao Paulo, Brazil
关键词
Biodiesel; free glycerol; gas chromatography; molecularly imprinted polymers; solid phase extraction; spectrophotometry; POLY(METHACRYLIC ACID); POLYVINYLIMIDAZOLE; CHEMISTRY; GRAPHENE;
D O I
10.1080/00032719.2020.1821040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work reports the development of a new analytical method for the determination of free glycerol in biodiesel samples using enzymatic-spectrophotometric assay combined with solid phase extraction (SPE) by molecularly imprinted poly(methacrylic acid) (MIP). The spectrophotometric method was performed using a commercial enzyme kit. The enzymatic-spectrophotometric method showed good analytical performance in terms of the linearity (0.998), limit of detection (7.70 x 10(-6)% w/w), limit of quantification (2.54 x 10(-5)% w/w), repeatability (0.42% to 7.91%), and recovery (99.4% to 112%). The analyses of several biodiesel samples by SPE and enzymatic-spectrophotometric method provided recovery values between 91.4% and 105%. Therefore, the high selectivity of molecularly imprinted polymer (MIP) was successfully applied to isolate free glycerol from biodiesel samples containing acylglycerols and methyl esters, and thereby allow enzymatic-spectrophometric based quantification. The developed method using SPE with MIP was efficient for the determination of free glycerol in biodiesel and the obtained results are in agreement with gas chromatrography (GC) that was used as a reference protocol.
引用
收藏
页码:1654 / 1667
页数:14
相关论文
共 29 条
[21]   A single-phase spectrophotometric procedure for in situ analysis of free glycerol in biodiesel [J].
Ribeiro, Mauricio S. ;
Rocha, Fabio R. P. .
MICROCHEMICAL JOURNAL, 2013, 106 :23-26
[22]   Synthesis and application of a peroxidase-like molecularly imprinted polymer based on hemin for selective determination of serotonin in blood serum [J].
Rodrigues Santos, Wilney de Jesus ;
Lima, Phabyanno Rodrigues ;
Teixeira Tarley, Cesar Ricardo ;
Hoehr, Nelci Fenalti ;
Kubota, Lauro Tatsuo .
ANALYTICA CHIMICA ACTA, 2009, 631 (02) :170-176
[23]  
Santos A. P. B., 2009, QUIMICA NOVA ESCOLA, V31
[24]   A reversed-phase air-assisted dispersive liquid-liquid microextraction coupled with colorimetric paper-based analytical device for the determination of glycerol, calcium and magnesium in biodiesel samples [J].
Shishov, Andrey ;
Trufanov, Ivan ;
Nechaeva, Daria ;
Bulatov, Andrey .
MICROCHEMICAL JOURNAL, 2019, 150
[25]   Sequential spectrofluorimetric determination of free and total glycerol in biodiesel in a multicommuted flow system [J].
Silva, Sidnei G. ;
Morales-Rubio, Angel ;
de La Guardia, Miguel ;
Rocha, Fabio R. P. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (01) :365-371
[26]   A flow injection procedure based on solenoid micro-pumps for spectrophotometric determination of free glycerol in biodiesel [J].
Silva, Sidnei G. ;
Rocha, Fabio R. P. .
TALANTA, 2010, 83 (02) :559-564
[27]  
Tarley César Ricardo Teixeira, 2005, Quím. Nova, V28, P1076
[28]   Evaluating the potential of thermal read-out techniques combined with molecularly imprinted polymers for the sensing of low-weight organic molecules [J].
van Grinsven, B. ;
Betlem, K. ;
Cleij, T. J. ;
Banks, C. E. ;
Peeters, M. .
JOURNAL OF MOLECULAR RECOGNITION, 2017, 30 (01)
[29]   A novel composite of SiO2-coated graphene oxide and molecularly imprinted polymers for electrochemical sensing dopamine [J].
Zeng, Yanbo ;
Zhou, Ying ;
Kong, Lei ;
Zhou, Tianshu ;
Shi, Guoyue .
BIOSENSORS & BIOELECTRONICS, 2013, 45 :25-33