Forcing lateral electron disequilibrium to spare lung tissue: a novel technique for stereotactic body radiation therapy of lung cancer

被引:7
作者
Disher, Brandon [1 ,2 ]
Hajdok, George [1 ,2 ,3 ]
Gaede, Stewart [1 ,2 ,3 ]
Mulligan, Matthew [1 ]
Battista, Jerry J. [1 ,2 ,3 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, Dept Phys & Engn, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Schulich Sch Med & Dent, Dept Med Biophys, London, ON N6A 5C1, Canada
[3] Univ Western Ontario, Schulich Sch Med & Dent, Dept Oncol, London, ON N6A 5C1, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
INHOMOGENEITY CORRECTION ALGORITHMS; DOSE CALCULATION ALGORITHMS; MONTE-CARLO-SIMULATION; 50 MV PHOTONS; HETEROGENEOUS MEDIA; SMALL FIELDS; ACUROS XB; RADIOTHERAPY; DENSITY; ENERGY;
D O I
10.1088/0031-9155/58/19/6641
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stereotactic body radiation therapy (SBRT) has quickly become a preferred treatment option for early-stage lung cancer patients who are ineligible for surgery. This technique uses tightly conformed megavoltage (MV) x-ray beams to irradiate a tumour with ablative doses in only a few treatment fractions. Small high energy x-ray fields can cause lateral electron disequilibrium (LED) to occur within low density media, which can reduce tumour dose. These dose effects may be challenging to predict using analytic dose calculation algorithms, especially at higher beam energies. As a result, previous authors have suggested using low energy photons (<10 MV) and larger fields (>5 x 5 cm(2)) for lung cancer patients to avoid the negative dosimetric effects of LED. In this work, we propose a new form of SBRT, described as LED-optimized SBRT (LED-SBRT), which utilizes radiotherapy (RT) parameters designed to cause LED to advantage. It will be shown that LED-SBRT creates enhanced dose gradients at the tumour/lung interface, which can be used to manipulate tumour dose, and/or normal lung dose. To demonstrate the potential benefits of LED-SBRT, the DOSXYZnrc (National Research Council of Canada, Ottawa, ON) Monte Carlo (MC) software was used to calculate dose within a cylindrical phantom and a typical lung patient. 6 MV or 18 MV x-ray fields were focused onto a small tumour volume (diameter similar to 1 cm). For the phantom, square fields of 1 x 1 cm(2), 3 x 3 cm(2), or 5 x 5 cm(2) were applied. However, in the patient, 3 x 1 cm(2), 3 x 2 cm(2), 3 x 2.5 cm(2), or 3 x 3 cm(2) field sizes were used in simulations to assure target coverage in the superior-inferior direction. To mimic a 180 degrees SBRT arc in the (symmetric) phantom, a single beam profile was calculated, rotated, and beams were summed at 1 degrees segments to accumulate an arc dose distribution. For the patient, a 360 degrees arc was modelled with 36 equally weighted (and spaced) fields focused on the tumour centre. A planning target volume (PTV) was generated by considering the extent of tumour motion over the patient's breathing cycle and set-up uncertainties. All patient dose results were normalized such that at least 95% of the PTV received at least 54 Gy (i.e. D95 = 54 Gy). Further, we introduce 'LED maps' as a novel clinical tool to compare the magnitude of LED resulting from the various SBRT arc plans. Results from the phantom simulation suggest that the best lung sparing occurred for RT parameters that cause severe LED. For equal tumour dose coverage, normal lung dose (2 cm outside the target region) was reduced from 92% to 23%, comparing results between the 18 MV (5 x 5 cm(2)) and 18 MV (1 x 1 cm(2)) arc simulations. In addition to reduced lung dose for the 18 MV (1 x 1 cm(2)) arc, maximal tumour dose increased beyond 125%. Thus, LED can create steep dose gradients to spare normal lung, while increasing tumour dose levels (if desired). In the patient simulation, a LED-optimized arc plan was designed using either 18 MV (3 x 1 cm(2)) or 6 MV (3 x 3cm(2)) beams. Both plans met the D95 dose coverage requirement for the target. However, the LED-optimized plan increased the maximum, mean, and minimum dose within the PTV by as much as 80 Gy, 11 Gy, and 3 Gy, respectively. Despite increased tumour dose levels, the 18 MV (3 x 1 cm(2)) arc plan improved or maintained the V20, V5, and mean lung dose metrics compared to the 6 MV (3 x 3 cm(2)) simulation. We conclude that LED-SBRT has the potential to increase dose gradients, and dose levels within a small lung tumour. The magnitude of tumour dose increase or lung sparing can be optimized through manipulation of RT parameters (e.g. beam energy and field size).
引用
收藏
页码:6641 / 6662
页数:22
相关论文
共 73 条
[1]   The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage [J].
Aarup, Lasse Rye ;
Nahum, Alan E. ;
Zacharatou, Christina ;
Juhler-Nottrup, Trine ;
Knoos, Tommy ;
Nystrom, Hakan ;
Specht, Lena ;
Wieslander, Elinore ;
Korreman, Stine S. .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :405-414
[2]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[3]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[4]   CONE-BEAM COMPUTED TOMOGRAPHIC IMAGE GUIDANCE FOR LUNG CANCER RADIATION THERAPY [J].
Bissonnette, Jean-Pierre ;
Purdie, Thomas G. ;
Higgins, Jane A. ;
Li, Winnie ;
Bezjak, Andrea .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03) :927-934
[5]   Measured lung dose correction factors for 50 MV photons [J].
Blomquist, M ;
Karlsson, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) :3225-3234
[6]   Comparison between a conventional treatment energy and 50 MV photons for the treatment of lung tumours [J].
Blomquist, M ;
Li, JS ;
Ma, CM ;
Zackrisson, B ;
Karlsson, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) :889-897
[7]   Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium [J].
Carrasco, P ;
Jornet, N ;
Duch, MA ;
Weber, L ;
Ginjaume, M ;
Eudaldo, T ;
Jurado, D ;
Ruiz, A ;
Ribas, M .
MEDICAL PHYSICS, 2004, 31 (10) :2899-2911
[8]   Fast on-site Monte Carlo tool for dose calculations in CT applications [J].
Chen, Wei ;
Kolditz, Daniel ;
Beister, Marcel ;
Bohle, Robert ;
Kalender, Willi A. .
MEDICAL PHYSICS, 2012, 39 (06) :2985-2996
[9]   Involved-field radiotherapy alone for early-stage non-small-cell lung cancer [J].
Cheung, PCF ;
Mackillop, WJ ;
Dixon, P ;
Brundage, MD ;
Youssef, YM ;
Zhou, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (03) :703-710
[10]   Investigation of a novel algorithm for true 4D-VMAT planning with comparison to tracked, gated and static delivery [J].
Chin, Erika ;
Otto, Karl .
MEDICAL PHYSICS, 2011, 38 (05) :2698-2707