Sensitive electrochemical immunoassay of metallothionein-3 based on K3[Fe(CN)6] as a redox-active signal and C-dots/Nafion film for antibody immobilization

被引:22
作者
Chen, Min [1 ,2 ]
Zhao, Chengfei [3 ]
Chen, Wei [3 ]
Weng, Shaohuang [3 ]
Liu, Ailin [3 ]
Liu, Qicai [4 ]
Zheng, Zongfu [5 ]
Lin, Jianhua [1 ]
Lin, Xinhua [3 ]
机构
[1] Fujian Med Univ, Affiliated Hosp 1, Dept Orthopaed, Fuzhou 350004, Peoples R China
[2] Fujian Med Univ, Affiliated Union Hosp, Dept Orthoped Surg, Fuzhou 350004, Peoples R China
[3] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Peoples R China
[4] Fujian Med Univ, Affiliated Hosp 1, Dept Clin Lab, Fuzhou 350004, Peoples R China
[5] PLA, Hosp 476, Fuzhou 350002, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
LABEL-FREE; CARBON NANODOTS; CARCINOEMBRYONIC ANTIGEN; IMMUNOSENSOR; GRAPHENE; SENSOR; OXIDE;
D O I
10.1039/c3an01351k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fabrication of a facile, sensitive, and versatile immunosensor for the quantification of metallothionein-3 (MT-3) is proposed in this work. The K-3[Fe(CN)(6)]-chitosan-glutaraldehyde (K-CS-GA) conjugate prepared from K-3[Fe(CN)(6)], chitosan and glutaraldehyde was employed as the redox-active signal source. Carbon nanodots (C-dots) were coupled with Nafion to form the nanocomposite architecture layer to carry antibodies (Abs). C-dots enhanced the electrochemical response of the proposed immunosensor to improve the detection sensitivity. The fabrication steps of the immunosensor were characterized using differential pulse voltammetry (DPV) and cyclic voltammetry (CV). Antigen determination was achieved via the decreased current response of the K-3[Fe(CN)(6)] caused by the insulated coupled antigen. The detected signals were proportional to the logarithm of the concentrations of MT-3 ranging from 5 pg mL(-1) to 20 ng mL(-1) with a detection limit of 2.5 pg mL(-1) in PBS. The proposed immunosensor showed high sensitivity, good selectivity and reproducibility. Furthermore, detection results using real serum samples showed the immunosensor's potential applications in clinical diagnostics.
引用
收藏
页码:7341 / 7346
页数:6
相关论文
共 37 条
  • [1] Enhanced Gold Nanoparticle Based ELISA for a Breast Cancer Biomarker
    Ambrosi, Adriano
    Airo, Federico
    Merkoci, Arben
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (03) : 1151 - 1156
  • [2] Luminescent Carbon Nanodots: Emergent Nanolights
    Baker, Sheila N.
    Baker, Gary A.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (38) : 6726 - 6744
  • [3] Electrochemical immunosensor for carcinoembryonic antigen based on nanosilver-coated magnetic beads and gold-graphene nanolabels
    Chen, Huafeng
    Tang, Dianping
    Zhang, Bing
    Liu, Bingqian
    Cui, Yuling
    Chen, Guonan
    [J]. TALANTA, 2012, 91 : 95 - 102
  • [4] A gold nanoparticles/sol-gel composite architecture for encapsulation of immunoconjugate for reagentless electrochemical immunoassay
    Chen, J
    Tang, JH
    Yan, F
    Ju, HX
    [J]. BIOMATERIALS, 2006, 27 (10) : 2313 - 2321
  • [5] Comparative Evaluation of Two Isobaric Labeling Tags, DiART and iTRAQ
    Chen, Zhen
    Wang, Quanhui
    Lin, Liang
    Tang, Qi
    Edwards, James L.
    Li, Shuwei
    Liu, Siqi
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (06) : 2908 - 2915
  • [6] An indirect perfluorosulfonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin
    Chetcuti, AF
    Wong, DKY
    Stuart, MC
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (18) : 4088 - 4094
  • [7] Electrochemical detection of triclosan at a glassy carbon electrode modifies with carbon nanodots and chitosan
    Dai, Hong
    Xu, Guifang
    Gong, Lingshan
    Yang, Caiping
    Lin, Yanyu
    Tong, Yuejin
    Chen, Jinghua
    Chen, Guonan
    [J]. ELECTROCHIMICA ACTA, 2012, 80 : 362 - 367
  • [8] Label-free electrochemiluminescent immunosensor for α-fetoprotein: performance of Nafion-carbon nanodots nanocomposite films as antibody carriers
    Dai, Hong
    Yang, Caiping
    Tong, Yuejin
    Xu, Guifang
    Ma, Xiuling
    Lin, Yanyu
    Chen, Guonan
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (25) : 3055 - 3057
  • [9] A graphene-based label-free voltammetric immunosensor for sensitive detection of the egg allergen ovalbumin
    Eissa, Shimaa
    L'Hocine, Lamia
    Siaj, Mohamed
    Zourob, Mohammed
    [J]. ANALYST, 2013, 138 (15) : 4378 - 4384
  • [10] ESCOSURAMUNIZ ADL, 2010, ELECTROCHEM COMMUN, V12, P859