Development of large area and of position-sensitive timing RPCs

被引:7
作者
Blanco, A
Marques, RF
Finck, C
Fonte, P [1 ]
Gobbi, A
Mendiratta, SK
Monteiro, J
Policarpo, A
Rozas, M
机构
[1] Univ Coimbra, LIP, Dept Fis, P-3004516 Coimbra, Portugal
[2] Univ Santiago de Compostela, Dept Fis Particulas, GENP, Santiago De Compostela, Spain
[3] GSI Darmstadt, Darmstadt, Germany
[4] ISEC, Coimbra, Portugal
[5] Univ Aveiro, Dept Fis, Aveiro, Portugal
关键词
gaseous detectors; time resolution; TOF; RPC;
D O I
10.1016/S0168-9002(01)01749-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Resistive Plate Chambers (RPC) made with glass and metal electrodes forming accurately spaced gas gaps of a few hundred micrometers have reached timing accuracies below 50 ps sigma with efficiencies above 99% for MIPs. This type of detector, operating at atmospheric pressure with non-flammable gases, seems well suited for large TOF systems, providing performances comparable to the scintillator-based TOF technology with significantly lower price per channel and being compatible with magnetic fields. In this work, we report recent developments of the timing RPC technology, including a large area counter (0.16 m(2)) and smaller, position-sensitive, single-gap counters. The latter devices are aimed to be applied in small and accurate TOF systems using a multilayer structure. The large counter has shown a timing resolution between 50 and 75 ps sigma over the whole active area, with 960 efficiency and very small timing tails, along with a longitudinal position-resolution of 1.2 cm sigma. The single-gap counters had a timing resolution of 55 ps sigma and a bi-dimensional position-resolution better than 3 mm FWHM. It was calculated that a 4-layer configuration of such counters would yield a time resolution of 33 ps a essentially free from timing tails. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 11 条
[1]  
AKINDINOV A, ALICEPUB9934
[2]  
BLANCO A, 2000, IN PRESS C P CERN
[3]  
BLANCO A, 2000, 2000 IEEE NUCL SCI S
[4]  
BLANCO A, IN PRESS NUCL INST A
[5]   Streamer suppression with SF6 in RPCs operated in avalanche mode [J].
Camarri, P ;
Cardarelli, R ;
Di Ciaccio, A ;
Santonico, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3) :317-324
[6]   High-resolution RPCs for large TOF systems [J].
Fonte, P ;
Marques, RF ;
Pinhao, J ;
Carolino, N ;
Policarpo, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (1-2) :295-301
[7]   A new high-resolution TOF technology [J].
Fonte, P ;
Smirnitski, A ;
Williams, MCS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (01) :201-204
[8]   High-resolution TOF with RPCs [J].
Fonte, P ;
Peskov, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :17-22
[9]   High-resolution timing of MIPs with RPCs - a model [J].
Fonte, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 456 (1-2) :6-10
[10]  
*FOPI COLL, 1998, UPGR FOPI DET SYST, P177