Non-white noise in fMRI: Does modelling have an impact?

被引:328
作者
Lund, TE
Madsen, KH
Sidaros, K
Luo, WL
Nichols, TE
机构
[1] Univ Copenhagen, Hvidovre Hosp, Danish Res Ctr Magnet Resonance, DK-2650 Hvidovre, Denmark
[2] Tech Univ Denmark, DK-2800 Lyngby, Denmark
[3] Merck & Co Inc, Whitehouse Stn, NJ 08889 USA
[4] Univ Michigan, Dept Biostat, Ann Arbor, MI 48109 USA
关键词
physiological noise; temporal autocorrelation; low-frequency drift;
D O I
10.1016/j.neuroimage.2005.07.005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the literature. Subsequently, we demonstrate, using diagnostic statistics, that removal of these contributions reduces first and higher order autocorrelation as well as non-normality in the residuals, thereby improving the validity of the drawn inferences. In addition, we also compare the performance of the NVR method to the whitening approach implemented in SPM2. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:54 / 66
页数:13
相关论文
共 35 条
  • [1] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [2] [Anonymous], P INT SOC MAGN RES M
  • [3] FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI
    BISWAL, B
    YETKIN, FZ
    HAUGHTON, VM
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 537 - 541
  • [4] Reduction of physiological fluctuations in fMRI using digital filters
    Biswal, B
    DeYoe, EA
    Hyde, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 107 - 113
  • [5] Noise suppression digital filter for functional magnetic resonance imaging based on image reference data
    Buonocore, MH
    Maddock, RJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 456 - 469
  • [6] Localization of cardiac-induced signal change in fMRI
    Dagli, MS
    Ingeholm, JE
    Haxby, JV
    [J]. NEUROIMAGE, 1999, 9 (04) : 407 - 415
  • [7] Frackowiak R. S., 2004, Human Brain Function
  • [8] FRANCKOWIAK RSJ, 1997, HUMAN BRAIN FUNCTION
  • [9] Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data
    Frank, LR
    Buxton, RB
    Wong, EC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 635 - 644
  • [10] Classical and Bayesian inference in neuroimaging: Applications
    Friston, KJ
    Glaser, DE
    Henson, RNA
    Kiebel, S
    Phillips, C
    Ashburner, J
    [J]. NEUROIMAGE, 2002, 16 (02) : 484 - 512