Tirofiban in Suspected Left Ventricular Assist Device Pump Thrombosis

被引:3
|
作者
Nei, Scott D. [1 ]
Wieruszewski, Patrick M. [1 ,2 ]
Orzel, Libby A. [3 ]
Ritchie, Brianne M. [4 ]
Stulak, John M. [5 ,6 ]
机构
[1] Mayo Clin, Dept Pharm, Rochester, MN 55905 USA
[2] Mayo Clin, Multidisciplinary Epidemiol & Translat Res Intens, Rochester, MN 55905 USA
[3] Ohio State Univ, Wexner Med Ctr, Dept Pharm, Columbus, OH 43210 USA
[4] CHI Hlth Lakeside Hosp, Dept Pharm, Omaha, NE USA
[5] Mayo Clin, Dept Cardiovasc Surg, Rochester, MN 55905 USA
[6] Mayo Clin, William J von Liebig Ctr Transplantat & Clin Rege, Rochester, MN 55905 USA
关键词
glycoprotein IIb; IIIa inhibitor; left ventricular assist device; mechanical circulatory support; pump thrombosis; tirofiban; PLATELET GLYCOPROTEIN IIB/IIIA; EPTIFIBATIDE; HEART; INHIBITION; HEPARIN;
D O I
10.1097/MAT.0000000000001083
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Antithrombotic optimization with a glycoprotein IIb/IIIa inhibitor has been used for the treatment of suspected pump thrombosis, but available literature with tirofiban is lacking. This study aims to describe the use of tirofiban for suspected pump thrombosis. This was a single-center cohort study of left ventricular assist device patients who received tirofiban for the treatment of suspected pump thrombosis from January 1, 2016 to July 31, 2017. Tirofiban was initiated at 0.1 mu g/kg/min in patients with normal renal function and subsequent dose adjustments for altered renal function or history of bleeding were employed. Success was defined as resolution of lactate dehydrogenase back to patients' known baseline. Fourteen patients were included for 16 total instances of tirofiban use during the time period. Tirofiban was continued for a median of 5 days (range: 0.3-35 days). Successful treatment was achieved in 12 of the 16 tirofiban uses (75%). Seven bleeding events occurred while on therapy, two major and five minor. This study showed a majority of patients achieved success with tirofiban for suspected pump thrombosis. For patients who are not current candidates for pump exchange or transplant, tirofiban may be considered a therapeutic medical management option.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 50 条
  • [31] Increase in Left Ventricular Assist Device Thrombosis
    Frazier, O. Howard
    NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (15): : 1464 - 1465
  • [32] The diagnosis of left ventricular assist device thrombosis
    H.Z.R. Gerds
    J. Brügemann
    M. Rienstra
    M.E. Erasmus
    Netherlands Heart Journal, 2015, 23 : 389 - 391
  • [33] Bivalirudin for left ventricular assist device thrombosis
    Phillip Weeks
    Adam Sieg
    Indranee Rajapreyar
    Sriram Nathan
    Marwan Jumean
    Manish Patel
    Rajko Radovancevic
    Biswajit Kar
    Igor Gregoric
    Journal of Thrombosis and Thrombolysis, 2018, 46 : 496 - 501
  • [34] Predictors for Left Ventricular Assist Device Thrombosis
    Shore, S.
    Soni, M.
    Hilbman, A.
    Patel, P.
    Mazurek, J. A.
    Justice, C.
    Guarracino, D.
    Molina, M.
    Wald, J.
    Atluri, P.
    Bermudez, C.
    Fox, A.
    Tanna, M.
    Goldberg, L. R.
    Rame, J.
    Birati, E. Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S366 - S366
  • [35] Left ventricular assist device thrombosis in the setting of left ventricular recovery
    Hurst, Thomas E.
    Moazami, Nader
    Starling, Randall C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : 622 - 623
  • [36] Role of thromboelastography in predicting and defining pump thrombosis in left ventricular assist device patients
    Xia, Ranran
    Varnado, Sara
    Graviss, Edward A.
    Nguyen, Duc T.
    Cruz-Solbes, Ana
    Guha, Ashrith
    Krisl, Jill C.
    THROMBOSIS RESEARCH, 2020, 192 : 29 - 35
  • [37] Cavitation in left ventricular assist device patients: a potential early sign of pump thrombosis
    Zuin, Marco
    Rigatelli, Gianluca
    Braggion, Gabriele
    Bacich, Daniela
    Thach Nguyen
    HEART FAILURE REVIEWS, 2020, 25 (06) : 965 - 972
  • [38] Left Ventricular Assist Device Pump Thrombosis: Is There a Role for Glycoprotein IIb/IIIa Inhibitors?
    Bellumkonda, Lavanya
    Subrahmanyan, Lakshman
    Jacoby, Daniel
    Bonde, Pramod
    ASAIO JOURNAL, 2014, 60 (01) : 134 - 136
  • [39] Cavitation in left ventricular assist device patients: a potential early sign of pump thrombosis
    Marco Zuin
    Gianluca Rigatelli
    Gabriele Braggion
    Daniela Bacich
    Thach Nguyen
    Heart Failure Reviews, 2020, 25 : 965 - 972
  • [40] HeartWare Left Ventricular Assist Device Pump Thrombosis A Shift Away From Ramp
    Rame, J. Eduardo
    Birati, Edo Y.
    JACC-HEART FAILURE, 2015, 3 (11) : 857 - 859