Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration

被引:60
作者
Li, BX [1 ]
Wang, DM [1 ]
Lv, HG [1 ]
Zhang, ZJ [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
flow-injection; chemiluminescence; partial least squares; simultaneous determination; Co2+ and Cu2+;
D O I
10.1016/j.talanta.2005.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection chemiluminescence (CL) system is proposed for simultaneous determination of Co2+ and Cu2+ using partial least squares (PLS) calibration. This method is based on the fact that both Co2+ and Cu2+ catalyse the CL reaction of luminol-H2O2, and that their kinetic characteristics of Co2+ and Cu2+ are significantly different in the luminol-H2O2 system. The CL intensity was measured and recorder at different reaction times of luminol-H2O2-Co2+-Cu2+, and the obtained data were processed by the chemometric approach of partial least squares. The experimental calibration set was composed of 16 sample solutions using an orthogonal calibration design for two component mixtures. The proposed method offers the potential advantages of high sensitivity, simplicity and rapidity for Co2+ and Cu2+ determination, and was successfully applied to the simultaneous determination of both analytes in real water sample. The present paper demonstrated that the simultaneous determination of two metal ions without any prior separation has been possible using flow-injection CL system. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 35 条
[1]   Determination of C-21 ketosteroids in serum using trifluoromethanesulfonic acid catalyzed precolumn dansylation and 1,1′-oxalyldiimidazole postcolumn peroxyoxalate chemiluminescence detection [J].
Appelblad, P ;
Jonsson, T ;
Bäckström, T ;
Irgum, K .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5002-5009
[2]   Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations [J].
Armenta, S ;
Garrigues, S ;
de la Guardia, M .
TALANTA, 2005, 65 (04) :971-979
[3]   Chemiluminescence detection in capillary electrophoresis [J].
Campana, AMG ;
Baeyens, WRG ;
Zhao, YN .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :A83-A88
[4]   Multivariate calibration applied to simultaneous chemiluminescence determination of cobalt and chromium [J].
Campíns-Falcó, Pilar ;
Tortajada-Genaro, L.A. ;
Meseguer-Lloret, S. ;
Bosch-Reig, F. .
2002, Springer Verlag (374) :7-8
[5]   Optimization of the simultaneous determination of Cr(VI) and Cr(VI) by ion chromatography with chemiluminescence detection [J].
Derbyshire, M ;
Lamberty, A ;
Gardiner, PHE .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4203-4207
[6]   Photoinduced spectrofluorimetric determination of fluoroquinolones in human urine by using three- and two-way spectroscopic data and multivariate calibration [J].
Espinosa-Mansilla, A ;
de la Peña, AM ;
Gómez, DG ;
Salinas, F .
ANALYTICA CHIMICA ACTA, 2005, 531 (02) :257-266
[7]   Partial least squares multicomponent fluorimetric determination of fluoroquinolones in human urine samples [J].
Espinosa-Mansilla, A ;
de la Peña, AM ;
Salinas, F ;
Gómez, DG .
TALANTA, 2004, 62 (04) :853-860
[8]   Dual amperometric biosensor device for analysis of binary mixtures of phenols by multivariate calibration using partial least squares [J].
Freire, RS ;
Ferreira, MMC ;
Durán, N ;
Kubota, LT .
ANALYTICA CHIMICA ACTA, 2003, 485 (02) :263-269
[9]   Solvent extraction coupled on-line to a reversed micellar mediated chemiluminescence detection system for trace-level determination of atropine [J].
Fujiwara, T ;
Mohammadzai, IU ;
Murayama, K ;
Kumamaru, T .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1715-1719
[10]   SELECTIVE CHLORINE DETERMINATION BY GAS-DIFFUSION FLOW-INJECTION ANALYSIS WITH CHEMI-LUMINESCENT DETECTION [J].
GORD, JR ;
GORDON, G ;
PACEY, GE .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :2-4