Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures

被引:7
|
作者
Augat, Peter [1 ,2 ]
Hoegel, Florian [3 ]
Stephan, Daniel [1 ]
Hoffmann, Stephanie [1 ]
Buehren, Volker [3 ]
机构
[1] Berufsgenossenschaftl Unfallklin Murnau, Inst Biomech, Prof Kuentscher Str 8, D-82418 Murnau, Murnau, Germany
[2] Paracelsus Med Univ Salzburg, Inst Biomech, Salzburg, Austria
[3] Berufsgenossenschaftl Unfallklin Murnau, Dept Trauma, Murnau, Germany
关键词
Biomechanical testing; analysis; implants; prosthetics; bone fracture; intramedullary nailing; plugs; tibia; trauma; osteosynthesis; MECHANICAL CONDITIONS; INTERLOCKING SCREWS; SHAFT FRACTURES; INITIAL PHASE; STABILITY; OSTEOSYNTHESIS; COMPRESSION; PERFORMANCE; DIAMETER; TRIAL;
D O I
10.1177/0954411916667968
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Treatment of distal tibia shaft fractures using intramedullary nailing requires stable fixation of the distal fragment to prevent malunion. Angular stable locking for intramedullary nails pledge to provide increased mechanical stability. This study tested the hypothesis that intramedullary nails with angular stable interlocking screws would have increased construct stiffness, reduced fracture gap movement and enhanced fatigue failure compared to nails with conventional locking having the same diameter. Biomechanical experiments were performed on 24 human cadaveric tibiae which obtained a distal fracture and were fixed by three different techniques: conventional locking with 8- and 10-mm-diameter nails and angular stable locking with 8-mm nails. Stiffness of the implant-bone construct and movement of the fragments were tested under axial loading and torsion. The constructs were tested to failure under cyclic fatigue loading. Analysis of variance and Kaplan-Meier survival analysis were used for statistical assessment. Axial stiffness of the 10-mm nail was about 50% larger compared to both 8-mm nail constructs independent of the type of locking mode (p<0.01). No differences were found in axial performance between angular stable and conventional locking neither under static nor under cyclic testing conditions (p>0.5). Angular stability significantly decreased the clearance under torsional load by more than 50% compared to both conventionally locked constructs (p=0.03). However, due to the larger nail diameter, the total interfragmentary motion was still smallest for the 10-mm nail construct (p<0.01). Although the 10-mm nail constructs survived slightly longer, differences between groups were minor and not statistically significant (p=0.4). Our hypothesis that angular stable interlocking of intramedullary nails would improve mechanical performance of distal tibia fracture fixation was not confirmed in a physiologically realistic loading scenario. Whether minor mechanical advantages provided by angular stability of the locking screws would improve biological tissue response cannot be concluded from this biomechanical study.
引用
收藏
页码:1016 / 1023
页数:8
相关论文
共 50 条
  • [31] Intramedullary Fixation of Distal Radius Fractures
    Harreld, Kevin
    Li, Zhongyu
    HAND CLINICS, 2010, 26 (03) : 363 - +
  • [32] Treatment of distal tibia fractures with intramedullary nail or plate: A meta-analysis
    Yu, Tao
    Li, Qianming
    Zhao, Hongmou
    Xia, Jiang
    Aubeeluck, Ashwin
    Yu, Guangrong
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2012, 28 (04) : 580 - 585
  • [33] Modified tibial nails for treating distal tibia fractures
    Gorczyca, JT
    McKale, T
    Pugh, K
    Pienkowski, T
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (01) : 18 - 22
  • [34] Winkelstabile Verriegelung von Marknägeln mit dem Angular Stable Locking System® (ASLS)Angle-stable fixation of intramedullary nails using the Angular Stable Locking System® (ASLS)
    D. Höntzsch
    M. Blauth
    R. Attal
    Operative Orthopädie und Traumatologie, 2011, 23 : 387 - 396
  • [35] Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing
    Foerch, Stefan
    Sandriesser, Sabrina
    von Rueden, Christian
    Mayr, Edgar
    Augat, Peter
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (05)
  • [36] Outcome and complications of distal tibia fractures treated with intramedullary nails versus minimally invasive plate osteosynthesis and the role of fibula fixation
    Kariya, Ankur
    Jain, Pramod
    Patond, Kisan
    Mundra, Anuj
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08) : 1487 - 1498
  • [37] UK Fixation of Distal Tibia Fractures (UK FixDT): protocol for a randomised controlled trial of 'locking' plate fixation versus intramedullary nail fixation in the treatment of adult patients with a displaced fracture of the distal tibia
    Achten, Juul
    Parsons, Nicholas R.
    McGuinness, Katie R.
    Petrou, Stavros
    Lamb, Sarah E.
    Costa, Matthew L.
    BMJ OPEN, 2015, 5 (09):
  • [38] Expandable intramedullary nails for fixation of tibial shaft fractures
    Ghafil, Dior
    Ackerman, Pieter
    Baillon, Renaud
    Verdonk, Rene
    Delince, Philippe
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (06): : 779 - 785
  • [39] Do Locked Compression Intramedullary Nails Improve the Biomechanical Stability of Distal Femoral Fractures?
    Wild, Michael
    Thelen, Simon
    Spoor, Vera
    Eichler, Christian
    Koebke, Juergen
    Jungbluth, Pascal
    Betsch, Marcel
    Windolf, Joachim
    Hakimi, Mohssen
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (04): : 832 - 837
  • [40] Tibia fractures, treatment whith intramedullary unfreased nails
    Del Gordo D'Amato, Roberto
    Castillo Suarez, Fabian
    Habeych Gonzalez, Alejandro
    Robles Bernal, Ramiro
    DUAZARY, 2008, 5 (01) : 4 - 8