Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure

被引:295
作者
Payne, RA [1 ]
Symeonides, CN [1 ]
Webb, DJ [1 ]
Maxwell, SRJ [1 ]
机构
[1] Univ Edinburgh, Western Gen Hosp, Clin Pharmacol Unit, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
preejection period; pulse-wave transit time;
D O I
10.1152/japplphysiol.00657.2005
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The arterial pulse-wave transit time can be measured between the ECG R-wave and the finger pulse (rPTT), and has been shown previously to have a linear correlation with blood pressure ( BP). We hypothesized that the relationship between rPTT, preejection period ( PEP; the R-wave/ mechanical cardiac delay), and BP would vary with different vasoactive drugs. Twelve healthy men ( mean age 22 yr) were studied. Beat-to-beat measurements were made of rPTT ( using ECG and photoplethysmograph finger probe), intra-arterial radial pressure, PEP ( using cardiac bioimpedance), and transit time minus PEP (pPTT). Four drugs ( glyceryl trinitrate, angiotensin II, norepinephrine, salbutamol) were administered intravenously over 15 min, with stepped dosage increase every 5 min and a 25- min saline washout between agents. All subjects in all conditions had a negative linear correlation ( R-2 = 0.39) between rPTT and systolic BP (SBP), generally constant between different drugs, apart from four subjects who had a positive rPTT/SBP correlation with salbutamol. The 95% limits of agreement between measured and rPTT-predicted SBP were +/- 17.0 mmHg. Beat-to-beat variability of rPTT showed better coherence with SBP variability than it did with heart rate variability ( P < 0.001). PEP accounted for a substantial and variable proportion of rPTT ( 12-35%). Diastolic ( DBP) and mean arterial BP ( MAP) correlated poorly with rPTT ( R-2 = 0.02 and 0.08, respectively) but better with pPTT ( rPTT corrected for PEP, R-2 = 0.41 and 0.45, respectively). The 95% limits of agreement between measured and pPTT-predicted DBP were +/- 17.3 mmHg. In conclusion, the negative correlation between rPTT and SBP is generally constant, even with marked hemodynamic perturbations. However, the relationship is not reliable enough for rPTT to be used as a surrogate marker of SBP, although it may be useful in assessing BP variability. DBP and MAP cannot be predicted from rPTT without correction for PEP. The significant contribution of PEP to rPTT means that rPTT should not be used as a marker of purely vascular function.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 40 条
[1]   Increase in pulse transit time to the foot after epidural anaesthesia treatment [J].
Babchenko, A ;
Davidson, E ;
Adler, D ;
Ginosar, Y ;
Kurz, V ;
Nitzan, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (06) :674-679
[2]   MEASURING BLOOD-PRESSURE IN PREGNANT-WOMEN - A COMPARISON OF DIRECT AND INDIRECT METHODS [J].
BROWN, MA ;
REITER, L ;
SMITH, B ;
BUDDLE, ML ;
MORRIS, R ;
WHITWORTH, JA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) :661-667
[3]   The effect of age on vascular compliance in man: which are the appropriate measures? [J].
Bulpitt, CJ ;
Cameron, JD ;
Rajkumar, C ;
Armstrong, S ;
Connor, M ;
Joshi, J ;
Lyons, D ;
Moioli, O ;
Nihoyannopoulos, P .
JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (11) :753-758
[4]   The aging of elastic and muscular arteries - A comparison of diabetic and nondiabetic subjects [J].
Cameron, JD ;
Bulpitt, CJ ;
Pinto, ES ;
Rajkumar, C .
DIABETES CARE, 2003, 26 (07) :2133-2138
[5]   The revision of the Declaration of Helsinki: past, present and future [J].
Carlson, RV ;
Boyd, KM ;
Webb, DJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2004, 57 (06) :695-713
[6]  
CARRUTHERS M, 1988, J AMBUL MONITORING, V1, P163
[7]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[8]   DETERMINATION OF PULSE-WAVE VELOCITIES WITH COMPUTERIZED ALGORITHMS [J].
CHIU, YC ;
ARAND, PW ;
SHROFF, SG ;
FELDMAN, T ;
CARROLL, JD .
AMERICAN HEART JOURNAL, 1991, 121 (05) :1460-1470
[9]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[10]  
GIBSON DG, 1971, POSTGRAD MED J, V47, P40