A comparison of two headless compression screws for operative treatment of scaphoid fractures

被引:26
|
作者
Grewal, Ruby [1 ]
Assini, Joseph [1 ]
Sauder, David [1 ]
Ferreira, Louis [1 ]
Johnson, Jim [1 ]
Faber, Kenneth [1 ]
机构
[1] St Josephs Hlth Care, Hand & Upper Limb Ctr, London, ON N6A 4L6, Canada
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2011年 / 6卷
关键词
CAST IMMOBILIZATION; FIXATION; WAIST;
D O I
10.1186/1749-799X-6-27
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw. Methods: Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed under fluoroscopic control using the manufacturer's recommended surgical technique. Compressive forces were measured during screw insertion. Recording continued for an additional 60s in order to measure any loss of compression after installation was complete. The peak and final interfragmentary compression were recorded and paired t-tests performed. Results: The mean peak compression generated by the Acutrak 2 Standard was greater than that produced by the Synthes compression screw (103.9 +/- 33.2 N vs. 88.7 +/- 38.6 N respectively, p = 0.13). The mean final interfragmentary compression generated by the Acutrak 2 screw (68.6 +/- 36.4 N) was significantly greater (p = 0.04) than the Synthes screw (37.2 +/- 26.8 N). Specimens typically reached a steady state of compression by 120-150s after final tightening. Conclusion: Peak interfragmentary compression observed during screw installation was similar for both screw systems. However, the mean interfragmentary compression generated by the Acutrak 2 Standard was significantly greater. Our study demonstrates that the Synthes headless compression screw experienced a greater loss of interfragmentary compressive force from the time of installation to the final steady state compression level. The higher post-installation compression of the Acutrak 2 Standard may be attributable to the greater number of threads throughout the entire length of the screw. The clinical significance of these results, are, at this point uncertain. We do demonstrate that a fully threaded design offers a more reliable compression that may translate to more predictable bony union.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Which Headless Compression Screw Produces the Highest Interfragmentary Compression Force in Scaphoid Fracture?
    Vishwanathan, Karthik
    Patel, Ravi
    Talwalkar, Sumedh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (05) : 548 - 564
  • [22] A Mechanical Comparison of the Compressive Force Generated by Various Headless Compression Screws and the Impact of Fracture Gap Size
    Ilyas, Asif M.
    Mahoney, Jonathan M.
    Bucklen, Brandon S.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (05): : 604 - 611
  • [23] Biomechanical comparison of three different compression screws for treatment of odontoid fractures evaluation of a new screw design
    Mueller, Jan-Uwe
    Mueller, Jonas
    Marx, Sascha
    Matthes, Marc
    Nowak, Stephan
    Schroeder, Henry Werner Siegfried
    Pillich, Dirk Thomas
    CLINICAL BIOMECHANICS, 2020, 77
  • [24] A systematic review of the treatment of acute fractures of the scaphoid
    Symes, T. H.
    Stothard, J.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (09) : 802 - 810
  • [25] Extended indications for retrograde intramedullary cannulated headless screws for proximal phalanx fractures
    Alabau-Rodriguez, Sergi
    Mir-Bullo, Xavier
    Barrera-Ochoa, Sergi
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (08) : 897 - 899
  • [26] Comparison of Minimally Invasive Operative Treatment with Conservative Treatment for Acute, Minimally Displaced Scaphoid Fractures at 12 Months' Follow-up
    Fyllos, Apostolos
    Komnos, George
    Koutis, Athanasios
    Bargiotas, Konstantinos
    Varitimidis, Sokratis
    Dailiana, Zoe
    JOURNAL OF WRIST SURGERY, 2021, 10 (03) : 216 - 223
  • [27] Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Two Parallel Headless, Tapered, Variable-Pitched, Titanium Compression Screws and Two Parallel 5.5 mm Stainless-Steel Cortical Screws
    Wolker, Ryan R. E.
    Carmalt, James L.
    Wilson, David G.
    VETERINARY SURGERY, 2009, 38 (07) : 861 - 867
  • [28] Conservative treatment for fractures of the scaphoid
    Chang, Nick
    Grewal, Ruby
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2020, 52 (05) : 399 - 403
  • [29] DIAGNOSIS AND TREATMENT OF SCAPHOID FRACTURES
    Bellantonio, V.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2013, 64 (04) : 453 - 458
  • [30] Deviations in positioning variable pitch screws-scaphoid waist fractures
    Graul, Isabel
    Lindner, Robert
    Schettler, Nicky
    Friedel, Reinhard
    Hofmann, Gunther O.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (02) : 347 - 351