A comparison of two headless compression screws for operative treatment of scaphoid fractures

被引:26
|
作者
Grewal, Ruby [1 ]
Assini, Joseph [1 ]
Sauder, David [1 ]
Ferreira, Louis [1 ]
Johnson, Jim [1 ]
Faber, Kenneth [1 ]
机构
[1] St Josephs Hlth Care, Hand & Upper Limb Ctr, London, ON N6A 4L6, Canada
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2011年 / 6卷
关键词
CAST IMMOBILIZATION; FIXATION; WAIST;
D O I
10.1186/1749-799X-6-27
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw. Methods: Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contralateral scaphoid designated to receive the opposite. Guide wires were inserted under fluoroscopic control. Following transverse osteotomy, the distal and proximal fragments were placed on either side of a custom load cell, to measure interfragmentary compression. Screws were placed under fluoroscopic control using the manufacturer's recommended surgical technique. Compressive forces were measured during screw insertion. Recording continued for an additional 60s in order to measure any loss of compression after installation was complete. The peak and final interfragmentary compression were recorded and paired t-tests performed. Results: The mean peak compression generated by the Acutrak 2 Standard was greater than that produced by the Synthes compression screw (103.9 +/- 33.2 N vs. 88.7 +/- 38.6 N respectively, p = 0.13). The mean final interfragmentary compression generated by the Acutrak 2 screw (68.6 +/- 36.4 N) was significantly greater (p = 0.04) than the Synthes screw (37.2 +/- 26.8 N). Specimens typically reached a steady state of compression by 120-150s after final tightening. Conclusion: Peak interfragmentary compression observed during screw installation was similar for both screw systems. However, the mean interfragmentary compression generated by the Acutrak 2 Standard was significantly greater. Our study demonstrates that the Synthes headless compression screw experienced a greater loss of interfragmentary compressive force from the time of installation to the final steady state compression level. The higher post-installation compression of the Acutrak 2 Standard may be attributable to the greater number of threads throughout the entire length of the screw. The clinical significance of these results, are, at this point uncertain. We do demonstrate that a fully threaded design offers a more reliable compression that may translate to more predictable bony union.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Two Parallel Headless Compression Screws for Scaphoid Fractures: Radiographic Analysis and Preliminary Outcome
    Diprinzio, Eliseo V.
    Dieterich, James D.
    Walsh, Amanda L.
    Warburton, Andrew J.
    Chang, Andy L.
    Hausman, Michael R.
    Kim, Jaehon M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023, 18 (08): : 1267 - 1274
  • [2] Arthroscopic treatment of unstable scaphoid fracture and nonunion with two headless compression screws and distal radius bone graft
    Cheng, Cong
    Jiang, Zongyuan
    Sun, Haoran
    Hu, Jiaping
    Ouyang, Yanggang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [3] Comparison of headless screws used in the treatment of proximal nonunion of scaphoid bone
    Gereli, Arel
    Nalbantoglu, Ufuk
    Sener, Ismail Ugur
    Kocaoglu, Baris
    Turkmen, Metin
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (07) : 1031 - 1035
  • [4] Headless Compression Screw Fixation of Scaphoid Fractures
    Fowler, John R.
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 351 - +
  • [5] Scaphoid Nonunions Treated With 2 Headless Compression Screws and Bone Grafting
    Garcia, Ryan M.
    Leversedge, Fraser J.
    Aldridge, J. Mack
    Richard, Marc J.
    Ruch, David S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (07): : 1301 - 1307
  • [6] The Durability of the Intrascaphoid Compression of Headless Compression Screws: In Vitro Study
    Gruszka, D. S.
    Burkhart, K. J.
    Nowak, T. E.
    Achenbach, T.
    Rommens, P. M.
    Mueller, L. P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (06): : 1142 - 1150
  • [7] Magnesium-Based Compression Screws in Acute Scaphoid Fractures and Nonunions
    Koenneker, Soeren
    Schaechinger, Ulrich
    Vogt, Peter M. M.
    WORLD JOURNAL OF SURGERY, 2023, 47 (05) : 1129 - 1135
  • [8] Which is the Best Solution for Achieving Maximal Interfragmentary Compression of the Scaphoid Fractures - One or Two Herbert Screws?
    Simeonov, L.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2023, 90 (01) : 34 - 40
  • [9] Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures
    Mandala, Meghana
    Shaunak, Shalin
    Kreitmair, Paul
    Phadnis, Joideep
    Guryel, Enis
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (03): : 1319 - 1325
  • [10] Tibiotalocalcaneal arthrodesis with headless compression screws
    Gong, Ji-Cheng
    Zhou, Bing-Hua
    Tao, Xu
    Yuan, Cheng-Song
    Tang, Kang-Lai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11