OPTIMAL DESIGN OF ARTERIAL BYPASS PROSTHESES DIAMETER

被引:2
|
作者
Stoytchev, S. [1 ]
Pallotti, G. [2 ]
Pettazzoni, P. [2 ]
机构
[1] Bulgarian Acad Sci, Inst Mech & Biomech, BU-1113 Sofia, Bulgaria
[2] Univ Bologna, Fac Med & Surg, I-40126 Bologna, Italy
关键词
Bypass; optimal diameter; mathematical model; wall shear stress; intimal thickening;
D O I
10.1142/S0219519401000222
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objectives of this paper are: (1) to analyze how the bypass diameter and the degree of the stenosis affect the flow-induced wall shear stresses in the stenotic and bypass vessels and (2) to propose a clinically usable method for a proper selection of the bypass diameter. The problem is solved in the following stages: First, the steady pressure and flow within the vessels are obtained using general laws of mass and energy conservation. Then, on the basis of modified Womersley's theory to take into account the nonlinear mechanical properties of the vessels, the oscillating pressure and flow within the vessels are calculated. They are used to derive expressions for the reflection coefficients at the distal (converging) bifurcation and to calculate wall shear stresses. We hypothesize that the minimal differences in the wall shear stresses of the normal artery, stenotic artery and the bypass graft mitigate the development of anastomotic neointimal hyperplasia and graft pseudo intima. Using cost functions, based on steady and mean wall shear stresses, we calculated the optimal value of the undeformed bypass diameter for various degrees of stenosis. We found that the sum of cross-sectional areas of the optimal graft and the stenotic artery (normalized with respect to the cross-sectional area of the normal artery) varies between 1.14 and 1.28, an interval, which is consistent with the findings of McDonald (1974) for the area of the major branches in the body. Thus we conclude that the results obtained are consistent with the stated hypothesis.
引用
收藏
页码:107 / 122
页数:16
相关论文
共 50 条
  • [41] SURFACE THROMBOGENICITY OF ARTERIAL PROSTHESES
    YATES, SG
    NAKAGAWA, Y
    BERGER, K
    SAUVAGE, LR
    SURGERY GYNECOLOGY & OBSTETRICS, 1973, 136 (01): : 12 - 16
  • [42] FAILURE OF DACRON ARTERIAL PROSTHESES
    DETERLIN.RA
    ARCHIVES OF SURGERY, 1974, 108 (01) : 13 - 13
  • [43] TEFLON FEMORAL ARTERIAL PROSTHESES
    WHITMAN, EJ
    JANES, JM
    IVINS, JC
    ARCHIVES OF SURGERY, 1961, 82 (01) : 153 - 162
  • [44] Optimal design of bypass location on heat exchanger networks
    Luo, Xionglin
    Sun, Lin
    Zhang, Junfeng
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2008, 59 (03): : 646 - 652
  • [45] Numerical design of an optimal bypass for a partially blocked artery
    Chen, Rongliang
    Cai, Xiao-Chuan
    2012 IEEE 26TH INTERNATIONAL PARALLEL AND DISTRIBUTED PROCESSING SYMPOSIUM WORKSHOPS & PHD FORUM (IPDPSW), 2012, : 1449 - 1456
  • [46] IMPORTANCE OF POROSITY IN ARTERIAL PROSTHESES
    FRY, WJ
    DEWEESE, MS
    KRAFT, RO
    ERNST, CB
    ARCHIVES OF SURGERY, 1964, 88 (05) : 836 - 842
  • [47] ORLON PROSTHESES IN ARTERIAL SURGERY
    TAYLOR, GW
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1956, 49 (06): : 339 - 340
  • [48] VERY SMALL-DIAMETER POLYURETHANE VASCULAR PROSTHESES WITH RAPID ENDOTHELIALIZATION FOR CORONARY-ARTERY BYPASS-GRAFTING
    OKOSHI, T
    SOLDANI, G
    GODDARD, M
    GALLETTI, PM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (05): : 791 - 795
  • [49] Optimal prosthetic graft design for small diameter vascular grafts
    Nishlbe, Toshiya
    Kondo, Yuka
    Muto, Akthito
    Dardik, Alan
    VASCULAR, 2007, 15 (06) : 356 - 360
  • [50] Optimal Design of the Large-diameter Spinning Torispherical Head
    Zhang Di
    Sheng Shuiping
    Gao Zengliang
    ADVANCES IN PRODUCT DEVELOPMENT AND RELIABILITY III, 2012, 544 : 194 - +