OPTIMAL DESIGN OF ARTERIAL BYPASS PROSTHESES DIAMETER

被引:2
|
作者
Stoytchev, S. [1 ]
Pallotti, G. [2 ]
Pettazzoni, P. [2 ]
机构
[1] Bulgarian Acad Sci, Inst Mech & Biomech, BU-1113 Sofia, Bulgaria
[2] Univ Bologna, Fac Med & Surg, I-40126 Bologna, Italy
关键词
Bypass; optimal diameter; mathematical model; wall shear stress; intimal thickening;
D O I
10.1142/S0219519401000222
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objectives of this paper are: (1) to analyze how the bypass diameter and the degree of the stenosis affect the flow-induced wall shear stresses in the stenotic and bypass vessels and (2) to propose a clinically usable method for a proper selection of the bypass diameter. The problem is solved in the following stages: First, the steady pressure and flow within the vessels are obtained using general laws of mass and energy conservation. Then, on the basis of modified Womersley's theory to take into account the nonlinear mechanical properties of the vessels, the oscillating pressure and flow within the vessels are calculated. They are used to derive expressions for the reflection coefficients at the distal (converging) bifurcation and to calculate wall shear stresses. We hypothesize that the minimal differences in the wall shear stresses of the normal artery, stenotic artery and the bypass graft mitigate the development of anastomotic neointimal hyperplasia and graft pseudo intima. Using cost functions, based on steady and mean wall shear stresses, we calculated the optimal value of the undeformed bypass diameter for various degrees of stenosis. We found that the sum of cross-sectional areas of the optimal graft and the stenotic artery (normalized with respect to the cross-sectional area of the normal artery) varies between 1.14 and 1.28, an interval, which is consistent with the findings of McDonald (1974) for the area of the major branches in the body. Thus we conclude that the results obtained are consistent with the stated hypothesis.
引用
收藏
页码:107 / 122
页数:16
相关论文
共 50 条
  • [1] CONNECTIONS BETWEEN DIAMETER AND FUNCTIONING OF SYNTHETIC ARTERIAL PROSTHESES
    BORNEMISZA, G
    GYURKO, G
    FURKA, I
    ACTA CHIRURGICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1967, 8 (04) : 331 - +
  • [2] EXPERIMENTAL STUDIES OF SMALL-DIAMETER ARTERIAL PROSTHESES
    BARROSDSA, AAB
    SAUVAGE, LR
    WALKER, MW
    BERGER, K
    ROBEL, SB
    YATES, SG
    BRITISH JOURNAL OF SURGERY, 1979, 66 (05) : 364 - 365
  • [3] Microstructure and Properties Analysis of Small Diameter ePTFE Arterial Prostheses
    Ji Xiao-ping
    Wang Lu
    Wang Fu-jun
    Guidoin, Robert
    2010 INTERNATIONAL FORUM ON BIOMEDICAL TEXTILE MATERIALS, PROCEEDINGS, 2010, : 459 - 464
  • [4] SUBCUTANEOUS ARTERIAL BYPASS GRAFTS IN MANAGEMENT OF FISTULAE BETWEEN BOWEL AND PLASTIC ARTERIAL PROSTHESES
    EHRENFELD, WK
    LORD, RS
    STONEY, RJ
    WYLIE, EJ
    ANNALS OF SURGERY, 1968, 168 (01) : 29 - +
  • [5] POLYETHER-URETHANE ELASTOMERS FOR SMALL-DIAMETER ARTERIAL PROSTHESES
    ANNIS, D
    LIFE SUPPORT SYSTEMS, 1987, 5 (01): : 47 - 52
  • [6] Preparation and evaluation of bicomponent and homogeneous polyester silk small diameter arterial prostheses
    Yang, Xiaoyuan
    Wang, Lu
    Guan, Guoping
    King, Martin W.
    Li, Yuling
    Peng, Lei
    Guan, Ying
    Hu, Xingyou
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2014, 28 (05) : 676 - 687
  • [7] Preparation and Mechanical Performance of Blended Polyester/Silk Small Diameter Arterial Prostheses
    杨小元
    王璐
    关国平
    关颖
    KING W Martin
    JournalofDonghuaUniversity(EnglishEdition), 2013, 30 (05) : 356 - 358
  • [8] Preparation and mechanical performance of blended polyester/silk small diameter arterial prostheses
    Yang, Xiao-Yuan
    Wang, Lu
    Guan, Guo-Ping
    Guan, Ying
    King, W Martin
    Journal of Donghua University (English Edition), 2013, 30 (05) : 356 - 358
  • [9] OPTIMAL OUTCOME AFTER TIBIAL ARTERIAL BYPASS
    SHAH, DM
    PATY, PSK
    LEATHER, RP
    CHANG, BB
    DARLING, RC
    FEUSTEL, PJ
    SURGERY GYNECOLOGY & OBSTETRICS, 1993, 177 (03): : 283 - 287
  • [10] EFFECT OF ELASTICITY OF PROSTHETIC WALL ON PATENCY OF SMALL-DIAMETER ARTERIAL PROSTHESES
    SEIFERT, KB
    ALBO, D
    KNOWLTON, H
    LYMAN, DJ
    SURGICAL FORUM, 1979, 30 : 206 - 208