Synchrotron X-ray microprobe and computed microtomography for characterization of nanocatalysts

被引:7
|
作者
Jones, KW
Feng, H
Lanzirotti, A
Mahajan, D
机构
[1] Brookhaven Natl Lab, Lab Earth & Environm Sci, Upton, NY 11973 USA
[2] Montclair State Univ, Montclair, NJ 07043 USA
[3] Univ Chicago, Consortium Adv Radiat Sources, Chicago, IL 60637 USA
[4] Brookhaven Natl Lab, Energy Sci Technol Dept, Upton, NY 11973 USA
[5] SUNY Stony Brook, Dept Mat Sci & Engn, Stony Brook, NY 11794 USA
关键词
synchrotron X-ray microprobe; computed microtomography; Fischer-Tropsch; catalysts; hydrocarbons;
D O I
10.1016/j.nimb.2005.07.177
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Gas-to-liquids (GTL) is a viable pathway for synthesis of clean fuels from natural gas. One of the attractive synthesis options is the Fischer Tropsch (F-T) method using an iron catalyst to yield a broad range of hydrocarbons. We collected catalyst samples during three separate F-T runs that utilized nanophase (mean particle diameter (MPD): 3 nm and 20-80 nm) and micrometer-sized (32.5 mu m) Fe2O3 that served as catalyst precursors. The collected samples were characterized with micro-X-ray fluorescence and computed microtomography at the National Synchrotron Light Source (NSLS). Results found with two different measurement techniques indicated that there was heterogeneity on a spatial scale corresponding to volumes of roughly 10(3) mu m(3). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 50 条
  • [21] BEATS: BEAmline for synchrotron X-ray microTomography at SESAME
    Iori, Gianluca
    Alzu'bi, Mustafa
    Abbadi, Anas
    Al Momani, Yazeed
    Hasoneh, Abdel Rahman
    Van Vaerenbergh, Pierre
    Cudin, Ivan
    Marcos, Jordi
    Ahmad, Abdalla
    Mohammad, Anas
    Matalgah, Salman
    Foudeh, Ibrahim
    Al Najdawi, Mohammad
    Amro, Adel
    Rehman, Abid Ur
    Abugharbiyeh, Mohammad
    Khrais, Rami
    Aljadaa, Amro
    Nour, Mohammad
    Al Mohammad, Hussam
    Al Omari, Farouq
    Salama, Majeda
    Fuste, Maria Jose Garcia
    Reyes-Herrera, Juan
    Morawe, Christian
    Attal, Maher
    Kasaei, Samira
    Chrysostomou, Charalambos
    Kolodziej, Tomasz
    Boruchowski, Mateusz
    Nowak, Pawel
    Wiechecki, Jaroslaw
    Fatima, Anis
    Ghigo, Andrea
    Wawrzyniak, Adriana, I
    Lorentz, Kirsi
    Paolucci, Giorgio
    Lehner, Frank
    Krisch, Michael
    Stampanoni, Marco
    Rack, Alexander
    Kaprolat, Axel
    Lausi, Andrea
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 1358 - 1372
  • [22] Synchrotron X-Ray microtomography of the interior microstructure of chocolate
    Luegger, Svenja K.
    Wilde, Fabian
    Duelger, Nihan
    Reinke, Lennart M.
    Kozhar, Sergii
    Beckmann, Felix
    Greving, Imke
    Vieira, Joselio
    Heinrich, Stefan
    Palzer, Stefan
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [23] APPLICATION OF X-RAY FOCUSING OPTICS TO A SYNCHROTRON BASED X-RAY MICROPROBE
    THOMPSON, AC
    UNDERWOOD, JH
    WU, Y
    GIAUQUE, RD
    JONES, KW
    RIVERS, ML
    FUTERNICK, RG
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 32 - 32
  • [24] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [25] USING SYNCHROTRON X-RAY MICROTOMOGRAPHY TO DETECT DEFECTS
    MILEWSKI, JO
    HMELO, AB
    DAMICO, KL
    DUNSMUIR, JH
    FERGUSON, SR
    WELDING JOURNAL, 1994, 73 (02) : 45 - 49
  • [26] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    Efimova, O. I.
    Khlebnikov, A. S.
    Senin, R. A.
    Voronin, P. A.
    Anokhin, K. V.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2013, 155 (04) : 413 - 416
  • [27] X-ray transmission microtomography using synchrotron radiation
    Lopes, RT
    Rocha, HS
    de Jesus, EFO
    Barroso, RC
    de Oliveira, LF
    Anjos, MJ
    Braz, D
    Moreira, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 604 - 607
  • [28] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    O. I. Efimova
    A. S. Khlebnikov
    R. A. Senin
    P. A. Voronin
    K. V. Anokhin
    Bulletin of Experimental Biology and Medicine, 2013, 155 : 413 - 416
  • [29] X-ray Microtomography at Shanghai Synchrotron Radiation Facility
    Chen, Rongchang
    Xie, Honglan
    Deng, Biao
    Du, Guohao
    Ren, Yuqi
    Wang, Yudan
    Zhou, Guangzhao
    Tan, Hai
    Yang, Yiming
    Xu, Liang
    Hu, Tao
    Li, Qiao
    Feng, Binggang
    Wang, Feixiang
    Xiao, Tiqiao
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [30] Characterization of quaternary metal oxide films by synchrotron X-ray fluorescence microprobe
    Perry, DL
    Thompson, AC
    Russo, RE
    Mao, XL
    Chapman, KL
    APPLIED SPECTROSCOPY, 1997, 51 (12) : 1781 - 1783