Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection

被引:11
作者
Fukushi, K
Ito, H
Kimura, K
Yokota, K
Saito, K
Chayama, K
Takeda, S
Wakida, S
机构
[1] Kobe Univ, Fac Maritime Sci, Higashinada Ku, Kobe, Hyogo 6580022, Japan
[2] Chibe Inst Sci, Fac Crisis Management, Choshi, Chiba 2880025, Japan
[3] Kobe Univ, Fac Human Dev, Nada Ku, Kobe, Hyogo 6578501, Japan
[4] Konan Univ, Fac Sci & Technol, Higashinada Ku, Kobe, Hyogo 6588501, Japan
[5] AIST, Natl Inst Adv Ind Sci & Technol, Ikeda, Osaka 5638577, Japan
关键词
water analysis; direct UV detection; alkaline background electrolyte; ammonium; ammonia;
D O I
10.1016/j.chroma.2005.10.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 34 条
[1]   Harmful effects of un-ionised ammonia on the zooplankton community in a deep waste treatment pond [J].
Arauzo, M .
WATER RESEARCH, 2003, 37 (05) :1048-1054
[2]  
Breadmore MC, 2001, ELECTROPHORESIS, V22, P2464
[3]   Quantitative assay fdr epinephrine in dental anesthetic solutions by capillary electrophoresis [J].
Britz-Mckibbin, P ;
Kranack, AR ;
Paprica, A ;
Chen, DDY .
ANALYST, 1998, 123 (07) :1461-1463
[4]   Flow system exploiting multicommutation to increase sample residence time for improved sensitivity.: Simultaneous determination of ammonium and ortho-phosphate in natural water [J].
Fernandes, RN ;
Reis, BF .
TALANTA, 2002, 58 (04) :729-737
[5]  
Freiser H., 1963, IONIC EQUILIBRIA ANA
[6]   Application of capillary electrophoresis to the analysis of inorganic ions in environmental samples [J].
Fukushi, K ;
Takeda, S ;
Chayama, K ;
Wakida, S .
JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) :349-362
[7]   ANALYSIS OF AMMONIA AND METHYLAMINES IN NATURAL-WATERS BY FLOW-INJECTION GAS-DIFFUSION COUPLED TO ION CHROMATOGRAPHY [J].
GIBB, SW ;
MANTOURA, RFC ;
LISS, PS .
ANALYTICA CHIMICA ACTA, 1995, 316 (03) :291-304
[8]  
GOTO T, 2001, P 18 S ION CHROM HIR, P54
[9]   Sequential flow injection analysis of ammonium and nitrate using gas phase molecular absorption spectrometry [J].
Haghighi, B ;
Kurd, SF .
TALANTA, 2004, 64 (03) :688-694
[10]   ENZYMATIC DETERMINATION OF AMMONIA IN LAKE WATER USING A SEMIAUTOMATIC ANALYZER [J].
HASHIMOTO, S ;
SUN, HY ;
OTSUKI, A ;
KAWAKAMI, S ;
MURATA, F ;
YOKOMIZO, M .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 48 (3-4) :155-161