Effect of drainage condition on the pullout characteristics of bucket foundations in sand

被引:15
作者
Hong, Seongho [1 ]
Vicent, Ssenyondo [1 ,2 ]
Gu, Kyo-Young [1 ]
Kim, Sung-Ryul [1 ]
机构
[1] Seoul Natl Univ, Dept Civil & Environm Engn, 1 Gwanak Ro, Seoul, South Korea
[2] Kyambogo Univ, Dept Civil & Environm Engn, POB 1, Kyambogo Kampala, Uganda
关键词
Bucket foundation; 1 g Model test; Pullout rate; Embedment ratio; Drainage condition; Drainage factor; MOMENT BEARING CAPACITIES; SUCTION CAISSONS; TRANSIENT; BEHAVIOR; ANCHORS;
D O I
10.1016/j.oceaneng.2022.111994
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
A series of 1 g experimental tests was conducted to investigate the effect of drainage condition on the pullout characteristics of bucket foundations in sand. Model buckets with a constant diameter of 150 mm and length-todiameter ratios of 1.5, 1.0 and 0.5 were employed with pullout rates ranging from 0.05 mm/s to 20 mm/s. The phenomena of heaving, gapping below the lid, and suction pressure have been investigated and discussed. The peak pullout load, peak suction pressure and heave increased with the increase in the pullout rate and L/D. The drainage factor was proposed to classify the drainage conditions during bucket pullout. The drainage factor is a function of the pullout rate and the inflow velocity. The inflow velocity converged to a nearly constant value defined as the critical inflow velocity. The pullout rates beyond the critical inflow velocity induced undrained conditions. The drainage conditions were classified as drained, partially drained, and undrained based on the proposed drainage factor. The drainage factor criterion reasonably classified the drainage conditions induced at peak pullout load.
引用
收藏
页数:13
相关论文
共 50 条
[1]  
Achmus M., 2014, Journal of Ocean and Wind Energy, V1, P231
[2]   EFFECT OF GAPPING ON THE TRANSIENT AND SUSTAINED UPLIFT CAPACITY OF A SHALLOW SKIRTED FOUNDATION IN CLAY [J].
Acosta-Martinez, Hugo E. ;
Gourvenec, Susan M. ;
Randolph, Mark F. .
SOILS AND FOUNDATIONS, 2010, 50 (05) :725-735
[3]   SUPERPILE SYSTEM - A FEASIBLE ALTERNATE FOUNDATION FOR TENSION LEG PLATFORMS IN DEEP-WATER [J].
ALBERT, LF ;
HOLTZ, RD ;
MAGRIS, E .
MARINE GEOTECHNOLOGY, 1989, 8 (02) :133-158
[4]  
[Anonymous], 2015, Int. J. Marit. Technol
[5]  
[Anonymous], 2009, Suction caissons in sand as tripod foundations for offshore wind turbines
[6]   Simplified load estimation and sizing of suction anchors for spar buoy type floating offshore wind turbines [J].
Arany, Laszlo ;
Bhattacharya, S. .
OCEAN ENGINEERING, 2018, 159 :348-357
[7]  
Bye A., 1995, OFFSHORE TECHNOLOGY
[8]  
Byrne B.W., 2000, THESIS OXFORD U
[9]   Experimental investigations of response of suction caissons to transient vertical loading [J].
Byrne, BW ;
Houlsby, GT .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2002, 128 (11) :926-939
[10]  
Cho Y, 2002, INT OFFSHORE POLAR E, P827