High aspect ratio Integrated Force Arrays

被引:0
作者
Bobbio, SM [1 ]
Smith, SW [1 ]
Zara, JM [1 ]
Goodwin-Johansson, S [1 ]
Gentry, KL [1 ]
Hudak, J [1 ]
Kerns, M [1 ]
Elliott, PC [1 ]
Rouse, BJ [1 ]
Borno, RT [1 ]
机构
[1] Univ N Carolina, Dept Elect & Comp Engn, Charlotte, NC 28223 USA
来源
SMART STRUCTURES AND MATERIALS 2001: SMART ELECTRONICS AND MEMS | 2001年 / 4334卷
关键词
actuator; effector; transducer; artificial muscle; synthetic muscle;
D O I
10.1117/12.436614
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Integrated Force Array (IFA) is a metallized polyimide actuator made up of a larger array of capacitive cells that deform when voltage is applied. The deformations of the individual cells add to produce an overall muscle-like compression of the array. In previously reported work deformations of up to 30% have been realized and the IFAs have been used as mechanical scanners in ultrasound imaging systems. The gaps of the capacitive cells are etched directly into the polyimide and oriented perpendicular to the plane of the array. Metal is deposited on the sidewalls of the etched features in order to form the plates of each capacitor. The force associated with the IFA motion is directly proportional to the height of the sidewall metal and thus to the thickness of the membrane. Until now, the thickness has been 2 mum with gap widths of 1 mum. In recent work, much higher aspect ratio IFAs (thicker but with the same gap width) have been fabricated in order to produce devices that operate with greater force and are much more robust devices.
引用
收藏
页码:298 / 308
页数:11
相关论文
共 10 条
[1]   Integrated force array: Positioning drive applications [J].
Bobbio, S ;
GoodwinJohansson, S ;
DuBois, T ;
Tranjan, F ;
Smith, S ;
Fair, R ;
Ball, C ;
Jacobson, J ;
Bartlett, C ;
Eleyan, N ;
Makki, H ;
Gupta, R .
SMART STRUCTURES AND MATERIALS 1996: SMART ELECTRONICS AND MEMS, 1996, 2722 :123-134
[2]  
BOBBIO S, 1991, Patent No. 5045166
[3]  
Bobbio S. M., 1993, Proceedings. IEEE. Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.93CH3265-6), P149, DOI 10.1109/MEMSYS.1993.296931
[4]   Integrated force array: Interface to external systems [J].
Bobbio, SM ;
Smith, SW ;
GoodwinJohansson, S ;
Fair, RB ;
DuBois, TD ;
Tranjan, FM ;
Hudak, J ;
Gupta, R ;
Makki, H .
SMART ELECTRONICS AND MEMS - SMART STRUCTURES AND MATERIALS 1997, 1997, 3046 :248-259
[5]  
GoodwinJohansson S, 1995, P SOC PHOTO-OPT INS, V2642, P52, DOI 10.1117/12.221183
[6]  
HILL ML, 1985, SOLID STATE TECHNOL, V28, P243
[7]  
JACOBS H, 1995, ANIM WELFARE, V4, P3
[8]  
LIN I, 1984, APPL PHYS LETT, V22, P185
[9]  
ZARA J, 2000, IN PRESS SYNTHETIC M
[10]   Intracardiac ultrasound scanner using a micromachine (MEMS) actuator [J].
Zara, JM ;
Bobbio, SM ;
Goodwin-Johansson, S ;
Smith, SW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (04) :984-993