Experimental and numerical study of smoke behavior in high-rise stairwells with open and closed windows

被引:14
|
作者
Ahn, Chan-Sol [1 ,2 ]
Kim, Doo-Young [2 ]
Park, Chanwoo [1 ]
Kim, Min-Woo [1 ]
Kim, Taegun [1 ]
Bang, Boo-Hyoung [3 ]
An, Seongpil [4 ,5 ]
Yarin, Alexander L. [6 ]
Yoon, Sam S. [1 ]
机构
[1] Korea Univ, Sch Mech Engn, Seoul 02841, South Korea
[2] Korea Inst Civil Engn & Bldg Technol, Fire Res Ctr, 283 Goyang Daero, Goyang Si 10223, South Korea
[3] Gyeonggi Univ Sci & Technol, Dept Energy Mech Engn, 269 Gyeonggigwagidae Ro, Siheung Si 15073, South Korea
[4] Sungkyunkwan Univ SKKU, SKKU Adv Inst Nanotechnol SAINT, Suwon 16419, South Korea
[5] Sungkyunkwan Univ SKKU, Dept Nano Engn, Suwon 16419, South Korea
[6] Univ Illinois, Dept Mech & Ind Engn, 842 W Taylor St, Chicago, IL 60607 USA
基金
新加坡国家研究基金会;
关键词
Smoke dynamics; High-rise stairwells; Turbulent plume; Flow visualization; Ventilation; Open-windows; LARGE-EDDY SIMULATION; BUOYANT PLUME; TEMPERATURE DISTRIBUTION; HOT GASES; FIRE; VENTILATION; MODEL; DYNAMICS; SHAFTS; FLOW;
D O I
10.1016/j.ijthermalsci.2020.106500
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study numerically and experimentally investigates the transport phenomena in buoyancy-driven smoke inside stairwells in a high-rise building. Hot smoke is supplied at the bottom of a small-scale, 2 m high stairwell prototype, and the smoke velocity and temperature are measured and compared with the corresponding numerical results. For all-windows-closed cases, the Fire Dynamics Simulator (FDS) model is used to predict the smoke velocity and temperature fields, which are found to be in good agreement with the experimental data. Obstruction caused by the stairs is observed to slow the smoke flow, which results in staggering and repeated vortical flows in all stairwells, confirmed by flow visualization. The flow path lines and vortex formation of the smoke inside the stairwells are visualized using the laser-induced fluorescence (LIF) method; these vortical structures also corresponded to the results of FDS simulation. Furthermore, the effect of heating power (Q) is investigated in the range of 60-180 W for experiments and 1-4 kW for simulations. Both temperature and velocity increase with Q. Having one open window at various building heights is shown to have small effect on the overall smoke temperature, although having many open windows causes a temperature drop owing to the inflow of fresh, cool air. Having one open window at various building heights slightly slows the smoke velocity, although the velocity is significantly decreased when many windows are open. Therefore, the intake of fresh air slows the overall smoke dynamics. Moreover, the effect of Q in the range of 2-20 MW over building heights of 60, 120, and 240 m is numerically simulated. The rate at which the smoke reaches high elevations is determined for all-windows-closed and all-windows-open cases based on our parametric studies. The smoke rise time (t) is shown to be proportional to similar to Q(-1/3) for all building heights, which is the same time scale as the one predicted by the plume theory. However, because of the complex internal geometry of confined buildings including stairwells and corridors, the magnitude of the smoke rise time for the building is much larger than that predicted by the plume theory. Therefore, the current experimental and numerical findings may be useful as design guidelines for building safety engineers.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] COSMO-Software for designing smoke control systems in high-rise buildings
    Black, W. Z.
    FIRE SAFETY JOURNAL, 2010, 45 (6-8) : 337 - 348
  • [42] Study of FDS simulations of buoyant fire-induced smoke movement in a high-rise building stairwell
    Zhao, Guoxiang
    Beji, Tarek
    Merci, Bart
    FIRE SAFETY JOURNAL, 2017, 91 : 276 - 283
  • [43] Performance assessment of stairwell smoke prevention techniques in a model high-rise building
    Sharma, Ankit
    Mishra, Kirti Bhushan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [44] Numerical Modeling of Cross-Transmission of Airborne Pollutants in a High-Rise Building Induced by Elevator Car Movement
    Zhang, Tengfei
    Wei, Guangxing
    Liu, Sumei
    APPLIED SCIENCES-BASEL, 2023, 13 (13):
  • [45] Numerical simulation of wind effects on super high-rise buildings considering wind veering with height based on CFD
    Feng, Chengdong
    Gu, Ming
    Zheng, Deqian
    JOURNAL OF FLUIDS AND STRUCTURES, 2019, 91
  • [46] A transient network model for cross-regional layered fire smoke diffusion in high-rise buildings
    Wan, Shanshan
    Zhou, Di
    Wang, Na
    Dang, Tianyu
    Qiu, Dongwei
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [47] Experimental and numerical studies of flows through and within high-rise building arrays and their link to ventilation strategy
    Hang, Jian
    Li, Yuguo
    Sandberg, Mats
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2011, 99 (10) : 1036 - 1055
  • [48] Acoustic wind tunnel experimental study of aerodynamic noise distribution in high-rise buildings
    Li, Jia 'nan
    Li, Zhengnong
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [49] A study on the stack effect of a super high-rise residential building in a severe cold region in China
    Man, Xiaoxin
    Lu, Yanyu
    Li, Guolei
    Wang, Yanling
    Liu, Jing
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (02) : 255 - 269
  • [50] Numerical Study on Effect of High-rise Building on Wind and Thermal Environments in Idealized Urban Array: Impacts of Planar Density
    Ding, P.
    Zhou, X.
    JOURNAL OF APPLIED FLUID MECHANICS, 2024, 17 (02) : 497 - 518