Accuracy of a Topical PET/CT Scanner on SUV Measurements of Small Volumes SUV

被引:0
作者
Schelper, Lutz Frank [1 ]
Oeri, Milan [2 ]
Buchmann, Inga [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Clin Radiol & Nucl Med, Lubeck, Germany
[2] Fraunhofer Inst Biomed Engn, St Ingbert, Germany
关键词
PET/CT; SUV; small structures; partial volume effect; recovery; reconstruction methods; TIME-OF-FLIGHT; STANDARDIZED UPTAKE VALUES; POINT-SPREAD FUNCTION; F-18-FDG PET/CT; IMAGE QUALITY; RECONSTRUCTION PARAMETERS; ACQUISITION TIME; IMPACT; QUANTIFICATION; TOMOGRAPHY;
D O I
10.2174/157340561104150727170915
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The subject of our study is to investigate the accuracy of a typical PET/CT system applying F-18-FDG to determine activity of small, hot volumes (HV) by phantom measurements under the impact of reconstruction techniques (RT) with and without Time-of-flight-Mode (TOF), activity concentration ratios into the phantom (ACR), density variations and relevant analysis parameters. Methods: We investigated a body phantom containing up to 7 spheres (d = 6-37mm) on a topical PET/CT system (SIEMENS BIOGRAPH mCT40). Recovery coefficients (RC) of small HVs dependent on the ACR and several RTs (iterative default (IT), iterative high-definition including the system Point-Spread-Function (HD), HD+TOF (UHD), filtered backprojection (FBP) and FBP+TOF (FBPT) were analysed. In addition, we determined RCs with respect to the matrix size, number of iterations, filter settings and a phantom insert of lung and bone density equivalent material. Results: The application of UHD in particular reproduces true activities of small volumes best, followed by HD, IT, FBPT and FBP. Lung and bone equivalent density inserts reduce the RCs by up to 19%. Especially for small HVs the RC can be raised by increasing the matrix size and iterations. Conclusions: Novel technology and analysis have a strong impact on the quantification. Hence, new guidelines are required enabling comparisons to other, prior systems. In order to get a precise activity determination of small structures, we recommend the UHD algorithm, high resolution matrix and high number of iterations with respect to acquisition time and administered activity.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 41 条
[1]   A Systematic Review of the Factors Affecting Accuracy of SUV Measurements [J].
Adams, Michael C. ;
Turkington, Timothy G. ;
Wilson, Joshua M. ;
Wong, Terence Z. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) :310-320
[2]  
Ahuja V, 1998, CANCER, V83, P918, DOI 10.1002/(SICI)1097-0142(19980901)83:5<918::AID-CNCR17>3.0.CO
[3]  
2-Y
[4]   Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters [J].
Akamatsu, Go ;
Ishikawa, Kaori ;
Mitsumoto, Katsuhiko ;
Taniguchi, Takafumi ;
Ohya, Nobuyoshi ;
Baba, Shingo ;
Abe, Koichiro ;
Sasaki, Masayuki .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) :1716-1722
[5]   Treatment monitoring by 18F-FDG PET/CT in patients with sarcomas:: Interobserver variability of quantitative parameters in treatment-induced changes in histopathologically responding and nonresponding tumors [J].
Benz, Matthias R. ;
Evilevitch, Vladimir ;
Allen-Auerbach, Martin S. ;
Eilber, Fritz C. ;
Phelps, Michael E. ;
Czernin, Johannes ;
Weber, Wolfgang A. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (07) :1038-1046
[6]  
Boellaard R, 2004, J NUCL MED, V45, P1519
[7]   FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0 [J].
Boellaard, Ronald ;
O'Doherty, Mike J. ;
Weber, Wolfgang A. ;
Mottaghy, Felix M. ;
Lonsdale, Markus N. ;
Stroobants, Sigrid G. ;
Oyen, Wim J. G. ;
Kotzerke, Joerg ;
Hoekstra, Otto S. ;
Pruim, Jan ;
Marsden, Paul K. ;
Tatsch, Klaus ;
Hoekstra, Corneline J. ;
Visser, Eric P. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee M. ;
Comans, Emile F. I. ;
Lammertsma, Adriaan A. ;
Paans, Anne M. ;
Willemsen, Antoon T. ;
Beyer, Thomas ;
Bockisch, Andreas ;
Schaefer-Prokop, Cornelia ;
Delbeke, Dominique ;
Baum, Richard P. ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) :181-200
[8]   The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials [J].
Boellaard, Ronald ;
Oyen, Wim J. G. ;
Hoekstra, Corneline J. ;
Hoekstra, Otto S. ;
Visser, Eric P. ;
Willemsen, Antoon T. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee ;
Paans, Anne M. ;
Comans, Emile F. I. ;
Pruim, Jan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (12) :2320-2333
[9]   Assessment of tumour response with 18F-fluorodeoxyglucose positron emission tomography using three-dimensional measures compared to SUVmax -: a phantom study [J].
Boucek, J. A. ;
Francis, R. J. ;
Jones, C. G. ;
Khan, N. ;
Turlach, B. A. ;
Green, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) :4213-4230
[10]  
Brunner E., 2002, NONPARAMETRIC ANAL L