Energy resolution and light yield non-proportionality of ZnSe: Te scintillator studied by large area avalanche photodiodes and photomultipliers

被引:36
作者
Balcerzyk, M [1 ]
Klamra, W
Moszynski, M
Kapusta, M
Szawlowski, M
机构
[1] Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] Royal Inst Technol, Dept Phys, S-10405 Stockholm, Sweden
[3] Adv Photon Inc, Camarillo, CA 93012 USA
关键词
ZnSe doped with Te; non-proportionality; X-ray detector; energy resolution;
D O I
10.1016/S0168-9002(01)01915-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ZnSe: Te scintillator has been studied by means of a photomultiplier with an extended bialkali photocathode, a large area avalanche photodiode (LAAPD) and a PIN photodiode. The light output was determined to be 28 300+/-1700 photons/MeV. Results indicate good proportionality for light output versus gamma-ray energy. Measurements of the 662 keV gamma-ray energy spectrum recorded using a LAAPD resulted in an energy resolution of 5.4+/-0.3%. Based on these results, an intrinsic energy resolution of 3.3+/-0.7% has been calculated. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:720 / 727
页数:8
相关论文
共 23 条
[1]   FLUORESCENT RESPONSE OF NAI(T1) CSI(T1) CSI(NA) AND CAF2(EU) TO X-RAYS AND LOW ENERGY GAMMA RAYS [J].
AITKEN, DW ;
BERON, BL ;
YENICAY, G ;
ZULLIGER, HR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) :468-+
[2]   DIELECTRIC FUNCTIONS AND OPTICAL-PARAMETERS OF SI, GE, GAP, GAAS, GASB, INP, INAS, AND INSB FROM 1.5 TO 6.0 EV [J].
ASPNES, DE ;
STUDNA, AA .
PHYSICAL REVIEW B, 1983, 27 (02) :985-1009
[3]  
Balcerzyk M., 1999, P 5 INT C IN SCINT T, P167
[4]   Non-proportionality in the scintillation response and the energy resolution obtainable with scintillation crystals [J].
Dorenbos, P ;
deHaas, JTM ;
vanEijk, CWE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2190-2202
[5]   NONLINEAR RESPONSE IN THE SCINTILLATION YIELD OF LU2SIO5 CE(3+) [J].
DORENBOS, P ;
DEHAAS, JTM ;
VANEIJK, CWE ;
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :735-737
[6]  
DORENBOS P, 1994, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE - 1994 IEEE CONFERENCE RECORD, VOLS 1-4, P304
[7]   Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber [J].
Fiorini, C ;
Longoni, A ;
Perotti, F ;
Labanti, C ;
Lechner, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2553-2560
[8]   Ellipsometric determination of optical constants for silicon and thermally grown silicon dioxide via a multi-sample, multi-wavelength, multi-angle investigation [J].
Herzinger, CM ;
Johs, B ;
McGahan, WA ;
Woollam, JA ;
Paulson, W .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (06) :3323-3336
[9]   A high-energy resolution observed from a YAP:Ce scintillator [J].
Kapusta, M ;
Balcerzyk, M ;
Moszynski, M ;
Pawelke, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 421 (03) :610-613
[10]  
KNOLL GF, 2000, RAD DETCTION MEASURE