Application of Chemometrics in Biosensing: A Brief Review

被引:29
作者
Martynko, Ekaterina [1 ]
Kirsanov, Dmitry [1 ]
机构
[1] St Petersburg State Univ, Inst Chem, Appl Chemometr Lab, St Petersburg 198504, Peterhoff, Russia
来源
BIOSENSORS-BASEL | 2020年 / 10卷 / 08期
基金
俄罗斯科学基金会;
关键词
biosensor; chemometrics; multivariate regression; classification; PCA; PLS; ANN; AMPEROMETRIC BIOSENSOR; BIOELECTRONIC TONGUE; PHOTOBACTERIUM-PHOSPHOREUM; ELECTROCHEMICAL BIOSENSORS; ANALYTICAL FIGURES; PHENOLIC-COMPOUNDS; IMPRINTED POLYMER; ARRAY; MIXTURES; TOXICITY;
D O I
10.3390/bios10080100
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The field of biosensing is rapidly developing, and the number of novel sensor architectures and different sensing elements is growing fast. One of the most important features of all biosensors is their very high selectivity stemming from the use of bioreceptor recognition elements. The typical calibration of a biosensor requires simple univariate regression to relate a response value with an analyte concentration. Nevertheless, dealing with complex real-world sample matrices may sometimes lead to undesired interference effects from various components. This is where chemometric tools can do a good job in extracting relevant information, improving selectivity, circumventing a non-linearity in a response. This brief review aims to discuss the motivation for the application of chemometric tools in biosensing and provide some examples of such applications from the recent literature.
引用
收藏
页数:20
相关论文
共 83 条
[71]   Chemometrics in foodomics: Handling data structures from multiple analytical platforms [J].
Skov, Thomas ;
Honore, Anders H. ;
Jensen, Henrik Max ;
Naes, Tormod ;
Engelsen, Soren B. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 60 :71-79
[72]   QSPR modeling of potentiometric sensitivity towards heavy metal ions for polymeric membrane sensors [J].
Soloviev, Vitaly ;
Varnek, Alexandre ;
Babain, Vasily ;
Polukeev, Valery ;
Ashina, Julia ;
Legin, Evgeny ;
Legin, Andrey ;
Kirsanov, Dmitry .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
[73]   Evaluation of joint toxicity of nitroaromatic compounds and copper to Photobacterium phosphoreum and QSAR analysis [J].
Su, Limin ;
Zhang, Xujia ;
Yuan, Xing ;
Zhao, Yuanhui ;
Zhang, Dongmei ;
Qin, Weichao .
JOURNAL OF HAZARDOUS MATERIALS, 2012, 241 :450-455
[74]   Electrochemical biosensors:: Recommended definitions and classification -: (Technical Report) [J].
Thévenot, DR ;
Toth, K ;
Durst, RA ;
Wilson, GS .
PURE AND APPLIED CHEMISTRY, 1999, 71 (12) :2333-2348
[75]   A polyion complex sensor array for markerless and noninvasive identification of differentiated mesenchymal stem cells from human adipose tissue [J].
Tomita, Shunsuke ;
Sakao, Miho ;
Kurita, Ryoji ;
Niwa, Osamu ;
Yoshimoto, Keitaro .
CHEMICAL SCIENCE, 2015, 6 (10) :5831-5836
[76]   Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality [J].
Tonning, E ;
Sapelnikova, S ;
Christensen, J ;
Carlsson, C ;
Winther-Nielsen, M ;
Dock, E ;
Solna, R ;
Skladal, P ;
Norgaard, L ;
Ruzgas, T ;
Emnéus, J .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (04) :608-617
[77]   A general approach to differential sensing using synthetic molecular receptors [J].
Umali, Alona P. ;
Anslyn, Eric V. .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2010, 14 (06) :685-692
[78]   Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue [J].
Valdes-Ramirez, G. ;
Gutierrez, M. ;
del Valle, M. ;
Ramirez-Silva, M. T. ;
Fournier, D. ;
Marty, J. -L. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1103-1108
[79]   Electrochemical glucose biosensors [J].
Wang, Joseph .
CHEMICAL REVIEWS, 2008, 108 (02) :814-825
[80]   PLS-regression:: a basic tool of chemometrics [J].
Wold, S ;
Sjöström, M ;
Eriksson, L .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 58 (02) :109-130