Influence of the third-order parameter on diffuse reflectance at small source-detector separations

被引:20
|
作者
Tian, HJ [1 ]
Liu, Y [1 ]
Wang, LJ [1 ]
机构
[1] Tianjin Univ, Coll Sci, Key Lab Optoelect Informat Tech Sci, Minist Educ, Tianjin 300072, Peoples R China
关键词
D O I
10.1364/OL.31.000933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatially resolved reflectance close to source has received a great deal of attention recently. This research is considered to develop a new noninvasive technique for measuring the optical properties of biological media. Using Monte Carlo simulations, we investigated the influence of third-order parameter delta on diffuse reflectance and found that the reflectance decreased with an increase of delta at a short source-detector separation of approximately 0.7-2 transport mean free paths. We show that the effects of two parameters, gamma and second-order parameter delta, on the reflectance are contrary. As a result the influence of the second-order parameter gamma on the reflectance is irregular when the condition Delta delta <<Delta gamma is not satisfied. (c) 2006 Optical Society of America.
引用
收藏
页码:933 / 935
页数:3
相关论文
共 50 条
  • [31] Influence of source-detector separation on diffuse correlation spectroscopy measurements of cerebral blood flow with a multilayered analytical model
    Zhao, Hongting
    Buckley, Erin M.
    NEUROPHOTONICS, 2022, 9 (03)
  • [32] Dual-slope diffuse optical imaging with a modular source-detector array
    Blaney, Giles
    Fernandez, Cristianne
    Sassaroli, Angelo
    Das, Tapan
    Fantini, Sergio
    NEURAL IMAGING AND SENSING 2023, 2023, 12365
  • [33] Design of a source-detector array for dual-slope diffuse optical imaging
    Blaney, Giles
    Sassaroli, Angelo
    Fantini, Sergio
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (09):
  • [34] Verification of a two-layer inverse Monte Carlo absorption model using multiple source-detector separation diffuse reflectance spectroscopy
    Sharma, Manu
    Hennessy, Ricky
    Markey, Mia K.
    Tunnell, James W.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 40 - 53
  • [35] Hemoglobin oxygen saturations in phantoms and in vivo from measurements of steady-state diffuse reflectance at a single, short source-detector separation
    Finlay, JC
    Foster, TH
    MEDICAL PHYSICS, 2004, 31 (07) : 1949 - 1959
  • [36] Considerations for image reconstruction with small source detector separations
    Dunn, A
    Boas, D
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 191 - 193
  • [37] Formulation of the third-order Gruneisen parameter at extreme compression
    Shanker, J.
    Sunil, K.
    Sharma, B. S.
    PHYSICA B-CONDENSED MATTER, 2012, 407 (12) : 2082 - 2083
  • [38] Estimation of the third-order parameter in extreme value statistics
    Goegebeur, Yuri
    de Wet, Tertius
    TEST, 2012, 21 (02) : 330 - 354
  • [39] Research on the third-order nonlinear parameter of bubbly watere
    Yi, Zhang
    Hui, Sun
    International Journal of Digital Content Technology and its Applications, 2012, 6 (12) : 274 - 280
  • [40] Estimation of the third-order parameter in extreme value statistics
    Yuri Goegebeur
    Tertius de Wet
    TEST, 2012, 21 : 330 - 354