Influence of the third-order parameter on diffuse reflectance at small source-detector separations

被引:20
|
作者
Tian, HJ [1 ]
Liu, Y [1 ]
Wang, LJ [1 ]
机构
[1] Tianjin Univ, Coll Sci, Key Lab Optoelect Informat Tech Sci, Minist Educ, Tianjin 300072, Peoples R China
关键词
D O I
10.1364/OL.31.000933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatially resolved reflectance close to source has received a great deal of attention recently. This research is considered to develop a new noninvasive technique for measuring the optical properties of biological media. Using Monte Carlo simulations, we investigated the influence of third-order parameter delta on diffuse reflectance and found that the reflectance decreased with an increase of delta at a short source-detector separation of approximately 0.7-2 transport mean free paths. We show that the effects of two parameters, gamma and second-order parameter delta, on the reflectance are contrary. As a result the influence of the second-order parameter gamma on the reflectance is irregular when the condition Delta delta <<Delta gamma is not satisfied. (c) 2006 Optical Society of America.
引用
收藏
页码:933 / 935
页数:3
相关论文
共 50 条
  • [1] Fluorescence and diffuse reflectance provide similar accuracy in recovering fluorophore concentration at short source-detector separations
    Roccabruna, Jacob R.
    Bridger, Karina G.
    Baran, Timothy M.
    JOURNAL OF MODERN OPTICS, 2022, 69 (12) : 699 - 704
  • [2] Monte Carlo study of diffuse reflectance at source-detector separations close to one transport mean free path
    Bevilacqua, F
    Depeursinge, C
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (12): : 2935 - 2945
  • [3] Determination of hemoglobin oxygen saturation from turbid media using reflectance spectroscopy with small source-detector separations
    Johns, M
    Giller, CA
    Liu, HL
    APPLIED SPECTROSCOPY, 2001, 55 (12) : 1686 - 1694
  • [4] Absolute absorber quantification in turbid media at small source-detector separations
    Willmann, S
    Terenji, A
    Osterholz, J
    Schwarzmaier, HJ
    Hering, P
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 74 (06): : 589 - 595
  • [5] Diffuse Correlation Spectroscopy at Short Source-Detector Separations: Simulations, Experiments and Theoretical Modeling
    Vishwanath, Karthik
    Zanfardino, Sara
    APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [6] Determination of optimal source-detector separation in measuring chromophores in layered tissue with diffuse reflectance
    罗云瀚
    崔厚欣
    谷筱玉
    刘蓉
    徐可欣
    ChineseOpticsLetters, 2005, (11) : 659 - 661
  • [7] Generalized diffusion approximation for highly absorbing media and small source-detector separations
    Zhu, D
    Wu, GL
    Luo, QM
    Gong, H
    ICO20: BIOMEDICAL OPTICS, 2006, 6026
  • [8] Influence of the scattering phase function on light transport measurements in turbid media performed with small source-detector separations
    Mourant, JR
    Boyer, J
    Hielscher, AH
    Bigio, IJ
    OPTICS LETTERS, 1996, 21 (07) : 546 - 548
  • [9] Time-resolved diffuse reflectance using small source-detector separation and fast single-photon gating
    Pifferi, Antonio
    Torricelli, Alessandro
    Spinelli, Lorenzo
    Contini, Davide
    Cubeddu, Rinaldo
    Martelli, Fabrizio
    Zaccanti, Giovanni
    Tosi, Alberto
    Dalla Mora, Alberto
    Zappa, Franco
    Cova, Sergio
    PHYSICAL REVIEW LETTERS, 2008, 100 (13)
  • [10] Optical property recovery with spatially-resolved diffuse reflectance at short source-detector separations using a compact fiber-optic probe
    Bridger, Karina G.
    Roccabruna, Jacob R.
    Baran, Timothy M.
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (12): : 7388 - 7404