The dependence of the dose response supralinearity of peak 5 in TLD-100 on recombination temperature

被引:11
作者
Horowitz, YS [1 ]
Satinger, D [1 ]
Oster, L [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
D O I
10.1093/oxfordjournals.rpd.a032807
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Isothermal readout of LiF:Mg,Ti (TLD-700) has recently been used to study the dependence of the supralinearity of peak 5 on recombination temperature. The results were interpreted to be in conflict with earlier results which investigated the effect of readout heating rate on the supralinearity of peak 5 in TLD-100. In this work the two experiments are inspected in greater detail. It is illustrated that the isothermal decay data is not in conflict with the heating rate data. However, the heating rate results do apparently indicate a strong transition in the temperature dependence of the relative strengths of the recombination and competitive cross sections at approximately 235 degrees C, which requires further study and analysis.
引用
收藏
页码:99 / 102
页数:4
相关论文
共 10 条
[1]   Investigation of the glow peak parameters, reusability and dosimetric precision of LiF:Mg,Cu,P at high heating rates up to 20 K.s-1 [J].
Ben-Amar, G ;
Ben-Shachar, B ;
Oster, L ;
Horowitz, Y ;
Horowitz, A .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :235-238
[2]  
BRAUNLICH P, SPRINGER TOPICS APPL, V37
[3]   TUNNELING RECOMBINATION OF TRAPPED ELECTRONS AND HOLES IN KCL-AGCL AND KCL-TLCL [J].
DELBECQ, CJ ;
TOYOZAWA, Y ;
YUSTER, PH .
PHYSICAL REVIEW B, 1974, 9 (10) :4497-4505
[5]  
Horowitz Y. S., 1984, Radiation Protection Dosimetry, V6, P17
[6]   KINETIC-ANALYSIS OF THERMOLUMINESCENCE - THEORETICAL AND PRACTICAL ASPECTS [J].
KIRSH, Y .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1992, 129 (01) :15-48
[7]   SUPRALINEARITY OF THE THERMOLUMINESCENCE GLOW-PEAK 5 OF LIF(TLD-700) OBTAINED WITH ISOTHERMAL MEASUREMENTS [J].
KITIS, G ;
CHARALMBOUS, S ;
TUYN, JWN .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (11) :2036-2040
[8]   The unified interaction model applied to the gamma ray induced supralinearity and sensitization of peak 5 in LiF:Mg,Ti (TLD-100) [J].
Mahajna, S ;
Horowitz, YS .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (18) :2603-2619
[9]   MECHANISMS OF SUPRALINEARITY IN LITHIUM-FLUORIDE THERMOLUMINESCENCE DOSIMETERS [J].
MISCHE, EF ;
MCKEEVER, SWS .
RADIATION PROTECTION DOSIMETRY, 1989, 29 (03) :159-175
[10]   Optical absorption and thermoluminescence studies in irradiated dosimetric LiF:Mg,Ti (TLD-100) [J].
Oster, L ;
Horowitz, YS ;
Issa, N .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :17-20