Electrostatic Switching and Selection of H3O+, NO+, and O2+• Reagent Ions for Selected Ion Flow-Drift Tube Mass Spectrometric Analyses of Air and Breath

被引:19
作者
Spanel, Patrik [1 ]
Spesyvyi, Anatolii [1 ]
Smith, David [1 ]
机构
[1] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223 8, Czech Republic
关键词
VOLATILE ORGANIC-COMPOUNDS; COLLISION-INDUCED DISSOCIATION; TRACE GAS-ANALYSIS; SIFT-MS; RATE CONSTANTS; PTR-MS; SENSITIVITY; QUANTIFICATION; AMMONIA; SAMPLES;
D O I
10.1021/acs.analchem.9b00530
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Soft chemical ionization mass spectrometry techniques, particularly the well-established proton transfer reaction mass spectrometry, PTR-MS, and selected ion flow tube mass spectrometry, SIFT-MS, are widely used for real-time quantification of volatile organic compounds in ambient air and exhaled breath with applications ranging from environmental science to medicine. The most common reagent ions H3O+, NO+, or O-2(+center dot) can be selected either by quadrupole mass filtering from a discharge ion source, which is relatively inefficient, or by switching the gas/vapor in the ion source, which is relatively slow. The chosen reagent ions are introduced into a flow tube or flow-drift tube reactor where they react with analyte molecules in sample gas. This article describes a new electrostatic reagent ion switching, ERIS, technique by which H3O+, NO+, and O-2(+center dot) reagent ions, produced simultaneously in three separate gas discharges, can be purified in post-discharge source drift tubes, switched rapidly, and selected for transport into a flow-drift tube reactor. The construction of the device and the ion molecule chemistry exploited to purify the individual reagent ions are described. The speed and sensitivity of ERIS coupled to a selected ion flow drift tube mass spectrometry, SIFDT-MS, is demonstrated by the simultaneous quantification of methanol with H3O+, acetone with NO+, and dimethyl sulfide with O-2(+center dot) reagent ions in single breath exhalations. The present ERIS approach is shown to be preferable to the previously used quadrupole filtering, as it increases analytical sensitivity of the SIFDT-MS instrument while reducing its size and the required number of vacuum pumps.
引用
收藏
页码:5380 / 5388
页数:9
相关论文
共 58 条
[1]  
Anicich V. G., 2003, JPL PUBLICATION, V03-19
[2]   Increased Sensitivity in Proton Transfer Reaction Mass Spectrometry by Incorporation of a Radio Frequency Ion Funnel [J].
Barber, Shane ;
Blake, Robert S. ;
White, Lain R. ;
Monks, Paul S. ;
Reich, Fraser ;
Mullock, Steve ;
Ellis, Andrew M. .
ANALYTICAL CHEMISTRY, 2012, 84 (12) :5387-5391
[3]   Proton-Transfer Reaction Mass Spectrometry [J].
Blake, Robert S. ;
Monks, Paul S. ;
Ellis, Andrew M. .
CHEMICAL REVIEWS, 2009, 109 (03) :861-896
[4]   Demonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds [J].
Blake, RS ;
Whyte, C ;
Hughes, CO ;
Ellis, AM ;
Monks, PS .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3841-3845
[5]   PTR3: An Instrument for Studying the Lifecycle of Reactive Organic Carbon in the Atmosphere [J].
Breitenlechner, Martin ;
Fischer, Lukas ;
Hainer, Markus ;
Heinritzi, Martin ;
Curtius, Joachim ;
Hansel, Armin .
ANALYTICAL CHEMISTRY, 2017, 89 (11) :5825-5832
[6]   Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry [J].
Bylinski, Hubert ;
Gebicki, Jacek ;
Dymerski, Tomasz ;
Namiesnik, Jacek .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2017, 47 (04) :340-358
[7]   SIMION for the personal computer in reflection [J].
Dahl, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 200 (1-3) :3-25
[8]   Volatile compounds profiling by using proton transfer reaction-time of flight-mass spectrometry (PTR-ToF-MS). The case study of dark chocolates organoleptic differences [J].
Deuscher, Zoe ;
Andriot, Isabelle ;
Semon, Etienne ;
Repoux, Marie ;
Preys, Sebastien ;
Roger, Jean-Michel ;
Boulanger, Renaud ;
Laboure, Helene ;
Le Quere, Jean-Luc .
JOURNAL OF MASS SPECTROMETRY, 2019, 54 (01) :92-119
[9]   Quantification of methane in humid air and exhaled breath using selected ion flow tube mass spectrometry [J].
Dryahina, Kseniya ;
Smith, D. ;
Spanel, P. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (09) :1296-1304
[10]   Real-Time Monitoring of Hazardous Air Pollutants [J].
Francis, Gregory J. ;
Langford, Vaughan S. ;
Milligan, Daniel B. ;
McEwan, Murray J. .
ANALYTICAL CHEMISTRY, 2009, 81 (04) :1595-1599