Grid convergence errors in hemodynamic solution of patient-specific cerebral aneurysms

被引:34
作者
Hodis, Simona [2 ]
Uthamaraj, Susheil [1 ]
Smith, Andrea L. [2 ]
Dennis, Kendall D. [1 ]
Kallmes, David F. [2 ,3 ]
Dragomir-Daescu, Dan [1 ,3 ]
机构
[1] Mayo Clin, Div Engn, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Rochester, MN 55905 USA
关键词
Solution accuracy; Grid sensitivity; Mixed-order method; Computational fluid dynamics; Wall shear stress; FLOW;
D O I
10.1016/j.jbiomech.2012.07.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Computational fluid dynamics (CFD) has become a cutting-edge tool for investigating hemodynamic dysfunctions in the body. It has the potential to help physicians quantify in more detail the phenomena difficult to capture with in vivo imaging techniques. CFD simulations in anatomically realistic geometries pose challenges in generating accurate solutions due to the grid distortion that may occur when the gild is aligned with complex geometries. In addition, results obtained with computational methods should be trusted only after the solution has been verified on multiple high-quality grids. The objective of this study was to present a comprehensive solution verification of the intra-aneurysmal flow results obtained on different morphologies of patient-specific cerebral aneurysms. We chose five patient-specific brain aneurysm models with different dome morphologies and estimated the grid convergence errors for each model. The grid convergence errors were estimated with respect to an extrapolated solution based on the Richardson extrapolation method, which accounts for the degree of grid refinement. For four of the five models, calculated velocity, pressure, and wall shear stress values at six different spatial locations converged monotonically, with maximum uncertainty magnitudes ranging from 12% to 16% on the finest grids. Due to the geometric complexity of the fifth model, the grid convergence errors showed oscillatory behavior; therefore, each patient-specific model required its own grid convergence study to establish the accuracy of the analysis. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2907 / 2913
页数:7
相关论文
共 21 条
[1]  
[Anonymous], 2010, Verification and Validation in Scientific Computing, DOI DOI 10.1017/CBO9780511760396
[2]  
Avital EJ, 2000, INT J NUMER METH FL, V33, P897, DOI 10.1002/1097-0363(20000730)33:6<897::AID-FLD37>3.0.CO
[3]  
2-4
[4]   Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture [J].
Cebral, J. R. ;
Mut, F. ;
Weir, J. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) :264-270
[5]  
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[6]   Assessment of numerical uncertainty around shocks and corners on blunt trailing-edge supercritical airfoils [J].
Chen, CFA ;
Lotz, RD ;
Thompson, BE .
COMPUTERS & FLUIDS, 2002, 31 (01) :25-40
[7]  
Cotta RM, 2006, Handbook of numerical heat transfer, V2nd
[8]  
Eca L., 2004, EUR C METH APPL SCI
[9]   Pulse wave velocity as a diagnostic Index: The pitfalls of tethering versus stiffening of the arterial wall [J].
Hodis, S. ;
Zamir, M. .
JOURNAL OF BIOMECHANICS, 2011, 44 (07) :1367-1373
[10]   Mechanical events within the arterial wall under the forces of pulsatile flow: A review [J].
Hodis, S. ;
Zamir, M. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) :1595-1602