Microstrain Around Dental Implants Supporting Fixed Partial Prostheses Under Axial and Non-Axial Loading Conditions, In Vitro Strain Gauge Analysis

被引:10
|
作者
Oliveira de Vasconcellos, Luis Gustavo [1 ]
Nishioka, Renato Sussumu [1 ]
Reis de Vasconcellos, Luana Marotta [2 ]
Balducci, Ivan [3 ,4 ]
Kojima, Alberto Noriyuki [1 ]
机构
[1] Sao Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil
[2] Sao Paulo State Univ UNESP, Dept Biosci & Buccal Diag, Sao Jose Dos Campos, Brazil
[3] Sao Paulo State Univ UNESP, Dept Social Dent, Sao Jose Dos Campos, Brazil
[4] Sao Paulo State Univ UNESP, Childrens Clin, Sch Dent Sao Jose dos Campos, Sao Jose Dos Campos, Brazil
关键词
Strain gauge analysis; dental implants; dental prosthesis; implant-supported dental prosthesis; INTERNAL HEXAGON; FRAMEWORK ALLOY; STRESS-ANALYSIS; ORAL IMPLANTS; PLACEMENT; BONE;
D O I
10.1097/SCS.0b013e31829ac83d
中图分类号
R61 [外科手术学];
学科分类号
摘要
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.
引用
收藏
页码:E546 / E551
页数:7
相关论文
共 10 条
  • [1] Effect of axial loads on implanted-supported partial fixed prostheses by strain gauge analysis
    Oliveira de Vasconcellos, Luis Gustavo
    Nishioka, Renato Sussumu
    Reis de Vasconcellos, Luana Marotta
    Braulino de Melo Nishioka, Lea Nogueira
    JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (06) : 610 - 615
  • [2] Axial Loads on Implant-Supported Partial Fixed Prostheses for External and Internal Hex Connections and Machined and Plastic Copings: Strain Gauge Analysis
    Oliveira de Vasconcellos, Luis Gustavo
    Kojima, Alberto Noriyuki
    Nishioka, Renato Sussumu
    Reis de Vasconcellos, Luana Marotta
    Balducci, Ivan
    Journal of Oral Implantology, 2015, 41 (02) : 149 - 154
  • [3] Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis
    Nicolas-Silvente, Ana, I
    Velasco-Ortega, Eugenio
    Ortiz-Garcia, Ivan
    Jimenez-Guerra, Alvaro
    Monsalve-Guil, Loreto
    Ayuso-Montero, Raul
    Gil, Javier
    Lopez-Lopez, Jose
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (23) : 1 - 11
  • [4] Stress Analysis of Axial and Tilted Implants in Full-arch Fixed Dentures Under Different Abutment Conditions
    Quinelli Mazaro, Jose Vitor
    da Silva, Cristina Ramos
    Gennari Filho, Humberto
    Zavanelli, Adriana Cristina
    de Mello, Caroline Cantieri
    Araujo Lemos, Cleidiel Aparecido
    Pellizzer, Eduardo Piza
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (03) : E249 - E252
  • [5] Straight and Offset Implant Placement under Axial and Nonaxial Loads in Implant-Supported Prostheses: Strain Gauge Analysis
    Abreu, Celina Wanderley
    Nishioka, Renato Sussumu
    Balducci, Ivan
    Consani, Rafael Leonardo Xediek
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (07): : 535 - 539
  • [6] Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis
    Oliveira, Helder
    Velasco, Aritza Brizuela
    Rios-Santos, Jose-Vicente
    Lasheras, Fernando Sanchez
    Lemos, Bernardo Ferreira
    Gil, Francisco Javier
    Carvalho, Alexandrine
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (13) : 1 - 17
  • [7] Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures.: A 5-year retrospective longitudinal study
    Koutouzis, Theofilos
    Wennstrom, Jan L.
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) : 585 - 590
  • [8] Pen-Implant Biomechanical Responses to Standard, Short-Wide, and Mini Implants Supporting Single Crowns Under Axial and Off-Axial Loading (an In Vitro Study)
    Kheiralla, Lamia Sayed
    Younis, Jihan Farouk
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (01) : 42 - 52
  • [9] Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study
    Elfadaly, Lamiaa Said
    Khairallah, Lamiaa Sayed
    Al Agroudy, Mona Atteya
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2017, 3
  • [10] Comparative evaluation to study the effect of implant support on complete fixed dental prosthesis fabricated with peek framework when implants placed in all-on-4 and all-on-6 situation, by strain gauge analysis and finite element analysis - An in vitro study
    Vinodh, Shanmathi
    Jingade, Ranganatha Rao K.
    Ajjikuttira, Ponnanna Appanna
    Kyathappa, Prathima
    Nataraj, Mamatha
    Chalana, B. O.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2023, 23 (04) : 373 - 378