Implementation of a nanochannel open/close valve into a glass nanofluidic device

被引:11
作者
Sano, Hiroki [1 ]
Kazoe, Yutaka [2 ]
Morikawa, Kyojiro [3 ]
Kitamori, Takehiko [3 ,4 ]
机构
[1] Univ Tokyo, Dept Appl Chem, Sch Engn, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Keio Univ, Dept Syst Design Engn, Fac Sci & Technol, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[3] Univ Tokyo, Collaborat Res Org Micro & Nano Multifunct Device, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[4] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Dept Power Mech Engn, 101,Sect 2,Kuang Fu Rd, Hsinchu 30013, Taiwan
基金
日本科学技术振兴机构;
关键词
Nanofluidics; Nanochannel; Valve; Femtoliter; Fluidic operation; LIQUID PROPERTIES; MICROCHIP;
D O I
10.1007/s10404-020-02383-x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In micro-/nanofluidics, channel open/close valves are fundamental to integrating fluid operations and realizing highly integrated analytical devices. Recently, we proposed a nanochannel open/close valve utilizing glass deformation and verified the principle of opening and closing nanochannels. Glass deformation sufficient to close the valve was achieved using a 45-mu m-thick glass sheet as a material of a nanofluidic device. However, since the device incorporates the thin glass sheet and is not robust enough to be used for repeated analyses, fluid operations utilizing the valve have not been verified sufficiently. Thus, in the present study, we fabricated a nanofluidic device implemented with a nanochannel open/close valve using rigid glass substrates of thicknesses on the order of 100 mu m, and verified fluid operations utilizing the valve. On a small part of the substrate, we designed and fabricated a 30-mu m-thick deformation section for the valve. The open/close operation and the performance of the valve were verified. The leakage of the valve was measured to be 2%, the response time was 0.9 s, and the number of repetitions was over 100,000. By utilizing the fabricated valve, we demonstrated fluid operations with femtoliter to picoliter volumes. Flow-switching within approximately 1 s and a flow control rate in the 63-1341 fL/s range was achieved. In addition, the fluid resistance of the valve was investigated both experimentally and numerically to establish a guideline for designing the valve. The valve developed and the design guidelines obtained will greatly contribute to integrated nanofluidic analytical devices.
引用
收藏
页数:11
相关论文
共 23 条
  • [1] Functional hydrogel structures for autonomous flow control inside microfluidic channels
    Beebe, DJ
    Moore, JS
    Bauer, JM
    Yu, Q
    Liu, RH
    Devadoss, C
    Jo, BH
    [J]. NATURE, 2000, 404 (6778) : 588 - +
  • [2] The Synthesis and Assembly of Polymeric Microparticles Using Microfluidics
    Dendukuri, Dhananjay
    Doyle, Patrick S.
    [J]. ADVANCED MATERIALS, 2009, 21 (41) : 4071 - 4086
  • [3] Nanochannels on a fused-silica microchip and liquid properties investigation by time-resolved fluorescence measurements
    Hibara, A
    Saito, T
    Kim, HB
    Tokeshi, M
    Ooi, T
    Nakao, M
    Kitamori, T
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6170 - 6176
  • [4] Highly Efficient and Ultra-small Volume Separation by Pressure-Driven Liquid Chromatography in Extended Nanochannels
    Ishibashi, Ryo
    Mawatari, Kazuma
    Kitamori, Takehiko
    [J]. SMALL, 2012, 8 (08) : 1237 - 1242
  • [5] Femtoliter nanofluidic valve utilizing glass deformation
    Kazoe, Yutaka
    Pihosh, Yuriy
    Takahashi, Hitomi
    Ohyama, Takeshi
    Sano, Hiroki
    Morikawa, Kyojiro
    Mawatari, Kazuma
    Kitamori, Takehiko
    [J]. LAB ON A CHIP, 2019, 19 (09) : 1686 - 1694
  • [6] Viscosity and Wetting Property of Water Confined in Extended Nanospace Simultaneously Measured from Highly-Pressurized Meniscus Motion
    Li, Lixiao
    Kazoe, Yutaka
    Mawatari, Kazuma
    Sugii, Yasuhiko
    Kitamori, Takehiko
    [J]. JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2012, 3 (17): : 2447 - 2452
  • [7] Extended-Nanofluidics: Fundamental Technologies, Unique Liquid Properties, and Application in Chemical and Bio Analysis Methods and Devices
    Mawatari, Kazuma
    Kazoe, Yutaka
    Shimizu, Hisashi
    Pihosh, Yuriy
    Kitamori, Takehiko
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (09) : 4068 - 4077
  • [8] Femtoliter Droplet Handling in Nanofluidic Channels: A Laplace Nanovalve
    Mawatari, Kazuma
    Kubota, Shogo
    Xu, Yan
    Priest, Craig
    Sedev, Rossen
    Ralston, John
    Kitamori, Takehiko
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (24) : 10812 - 10816
  • [9] Microflow Systems for Chemical Synthesis and Analysis: Approaches to Full Integration of Chemical Process
    Mawatari, Kazuma
    Kazoe, Yutaka
    Aota, Arata
    Tsukahara, Takehiko
    Sato, Kae
    Kitamori, Takehiko
    [J]. JOURNAL OF FLOW CHEMISTRY, 2011, 1 (01) : 3 - 12
  • [10] Cytokine analysis on a countable number of molecules from living single cells on nanofluidic devices
    Nakao, Tatsuro
    Kazoe, Yutaka
    Mori, Emi
    Morikawa, Kyojiro
    Fukasawa, Takemichi
    Yoshizaki, Ayumi
    Kitamori, Takehiko
    [J]. ANALYST, 2019, 144 (24) : 7200 - 7208