Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT

被引:22
|
作者
Chun, Se Young [1 ,2 ,3 ]
Fessler, Jeffrey A. [1 ]
Dewaraja, Yuni K. [2 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[3] Ulsan Natl Inst Sci & Technol, Sch Elect & Comp Engn, Ulsan, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 17期
关键词
TUMOR DOSE-RESPONSE; 3-DIMENSIONAL DOSIMETRY; RADIONUCLIDE THERAPY; RECONSTRUCTION; RADIOIMMUNOTHERAPY; REGULARIZATION; LYMPHOMA; IMAGES; PRIORS; PET;
D O I
10.1088/0031-9155/58/17/6225
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantitative SPECT techniques are important for many applications including internal emitter therapy dosimetry where accurate estimation of total target activity and activity distribution within targets are both potentially important for dose-response evaluations. We investigated non-local means (NLM) post-reconstruction filtering for accurate I-131 SPECT estimation of both total target activity and the 3D activity distribution. We first investigated activity estimation versus number of ordered-subsets expectation-maximization (OSEM) iterations. We performed simulations using the XCAT phantom with tumors containing a uniform and a non-uniform activity distribution, and measured the recovery coefficient (RC) and the root mean squared error (RMSE) to quantify total target activity and activity distribution, respectively. We observed that using more OSEM iterations is essential for accurate estimation of RC, but may or may not improve RMSE. We then investigated various post-reconstruction filtering methods to suppress noise at high iteration while preserving image details so that both RC and RMSE can be improved. Recently, NLM filtering methods have shown promising results for noise reduction. Moreover, NLM methods using high-quality side information can improve image quality further. We investigated several NLM methods with and without CT side information for I-131 SPECT imaging and compared them to conventional Gaussian filtering and to unfiltered methods. We studied four different ways of incorporating CT information in the NLM methods: two known (NLM CT-B and NLM CT-M) and two newly considered (NLM CT-S and NLM CT-H). We also evaluated the robustness of NLM filtering using CT information to erroneous CT. NLM CT-S and NLM CT-H yielded comparable RC values to unfiltered images while substantially reducing RMSE. NLMCT-S achieved -2.7 to 2.6% increase of RC compared to no filtering and NLM CT-H yielded up to 6% decrease in RC while other methods yielded lower RCs than them: Gaussian filtering (up to 11.8% decrease in RC), NLM method without CT (up to 9.5% decrease in RC), and NLM CT-M and NLM CT-B (up to 19.4% decrease in RC). NLM CT-S and NLM CT-H achieved 8.2 to 33.9% and -0.9 to 36% decreased RMSE on tumors compared to no filtering respectively while other methods yielded less reduced or increased RMSE: Gaussian filtering (up to 7.9% increase in RMSE), NLM method without CT (up to 18.3% increase in RMSE), and NLM CT-M and NLM CT-B (up to 31.5% increase in RMSE). NLM CT-S and NLM CT-H also yielded images with tumor shapes that better-matched the true shapes than other methods. All NLM methods using CT information were robust to small misregistration between SPECT and CT, but NLM CT-S and NLM CT-H were more sensitive than NLM CT-M and NLM CT-B to missing CT information.
引用
收藏
页码:6225 / 6240
页数:16
相关论文
共 50 条
  • [1] Non-Local Means Methods Using CT Side Information for I-131 SPECT Image Reconstruction
    Chun, Se Young
    Fessler, Jeffrey A.
    Dewaraja, Yuni K.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3362 - 3366
  • [2] Post-reconstruction partial volume correction of PET using CT side information
    Moody, Jonathan
    Lee, Benjamin
    Ficaro, Edward
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [3] Investigation on Parameter Selection of Non-Local Means Filters using CT Side Information for Multiple I-131 SPECT Scans
    Chun, Se Young
    Dewaraja, Yuni K.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] 4D Non-Local Means Post-Filtering For Cardiac Gated SPECT
    Song, Chao
    Yang, Yongyi
    Qi, Wenyuan
    Wernick, Miles N.
    Pretorius, P. Hendrik
    King, Michael A.
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 1200 - 1204
  • [5] 4D non-local means post-filtering for cardiac gated SPECT
    Song, Chao
    Yang, Yongyi
    Pretorius, P. Hendrik
    King, Michael A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [6] An iterative tomosynthesis reconstruction using total variation combined with non-local means filtering
    Ertas, Metin
    Yildirim, Isa
    Kamasak, Mustafa
    Akan, Aydin
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [7] An iterative tomosynthesis reconstruction using total variation combined with non-local means filtering
    Metin Ertas
    Isa Yildirim
    Mustafa Kamasak
    Aydin Akan
    BioMedical Engineering OnLine, 13
  • [8] Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging
    Dewaraja, Yuni K.
    Koral, Kenneth F.
    Fessler, Jeffrey A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (09): : 2523 - 2539
  • [9] Myocardial SPECT reconstruction using EM and OSEM with compensation for distance dependent resolution and post-reconstruction filtering.
    Lau, YH
    Hutton, BF
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 66 - 66
  • [10] Estimation of Mueller matrices using non-local means filtering
    Faisan, Sylvain
    Heinrich, Christian
    Sfikas, Giorgos
    Zallat, Jihad
    OPTICS EXPRESS, 2013, 21 (04): : 4424 - 4438