The Effect of JPEG2000 Compression on Detection of Skull Fractures

被引:5
作者
McEntee, Mark F. [1 ,2 ]
Nikolovski, Ines [3 ]
Bourne, Roger [1 ,2 ]
Pietrzyk, Mariusz W. [1 ,2 ]
Evanoff, Michael G. [4 ]
Brennan, Patrick C. [1 ,2 ]
Tay, Kevin L. [5 ]
机构
[1] Univ Sydney, Discipline Med Radiat Sci, Fac Hlth Sci, Sydney, NSW 2141, Australia
[2] Univ Sydney, Brain & Mind Inst, Fac Hlth Sci, Sydney, NSW 2141, Australia
[3] Royal N Shore Hosp, Sydney, NSW, Australia
[4] Amer Board Radiol, Tucson, AZ USA
[5] I MED Network, Sydney, NSW, Australia
关键词
JPEG2000; compression; skull fractures; CT; head; VISUALLY LOSSLESS THRESHOLD; CT IMAGES; WAVELET COMPRESSION; ABDOMINAL CT; IRREVERSIBLE COMPRESSION; OBSERVER PERFORMANCE; CHEST RADIOGRAPHS; MEDICAL IMAGES; LUNG; WRIST;
D O I
10.1016/j.acra.2013.01.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rational and Objectives: To investigate the effect of the Joint Photographic Experts Group (JPEG2000) 30:1 and 60:1 lossy compression on the detection of cranial vault fractures when compared to JPEG2000 lossless compression. Materials and Methods: Fifty cranial computed tomography (CT) images were processed with three different level of JPEG2000 compression (lossless, 30:1 lossy, and 60:1 lossy) creating three sets of images. These were presented to five musculoskeletal specialists and five neuroradiologists. Each reader read at two of the three compression levels. Twenty-two cases contained a single fracture; the remaining 28 cases contained no fractures. Observers were asked to identify the presence or absence of a fracture, to locate its site, and rate their degree of confidence. Receiver operating characteristic (ROC), jackknife free-response receiver operating characteristic (JAFROC) and the Dorfman-Berbaum-Metz multiple reader multiple case (DBM-MRMC) analyses were used to explore differences between the lossless and lossy compressed images. Results: JPEG2000 lossless and 30:1 lossy compression demonstrated no significant difference in their performance with JAFROC and DBM-MRMC analysis (P <.416); however, JPEG2000 30:1 lossy compression demonstrated significantly better performance than 60:1 lossy compression (P <.016). A significant increase in misplaced confidence ratings was also seen with 60:1 (P <.037) over 30:1 lossy and lossless compression. Conclusion: JPEG2000 60:1 compression degrades the detection of skull fractures significantly while increasing the confidence with which readers rate fractures compared with 30:1 lossy and lossless compression. JPEG2000 30:1 lossy compression does not significantly change performance when compared to JPEG2000 lossless for the detection of skull fractures on CT.
引用
收藏
页码:712 / 720
页数:9
相关论文
共 38 条
[1]   Differences in compression artifacts on thin- and thick-section lung CT images [J].
Bajpa, Vasundhara ;
Lee, Kyoung Ho ;
Kim, Bohyoung ;
Kim, Kil Joong ;
Kim, Tae Jung ;
Kim, Young Hoon ;
Kang, Heung Sik .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :W38-W43
[2]  
BAJPAI V, 2012, P SOC PHOTO-OPT INS, V8318
[3]   ROC assessment of compressed wrist radiographs [J].
Baudin, O ;
Baskurt, A ;
Moll, T ;
Prost, R ;
Revel, D ;
Ottes, F ;
Khamadja, M ;
Amiel, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1996, 22 (03) :228-231
[4]   IMAGE DATA-COMPRESSION IN MAGNIFICATION HAND RADIOGRAPHS [J].
BRAMBLE, JM ;
COOK, LT ;
MURPHEY, MD ;
MARTIN, NL ;
ANDERSON, WH ;
HENSLEY, KS .
RADIOLOGY, 1989, 170 (01) :133-136
[5]   Ambient lighting: Effect of illumination on soft-copy viewing of radiographs of the wrist [J].
Brennan, Patrick C. ;
McEntee, Mark ;
Evanoff, Michael ;
Phillips, Peter ;
O'Connor, William T. ;
Manning, David J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :W177-W180
[6]   Validation and Statistical Power Comparison of Methods for Analyzing Free-response Observer Performance Studies [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2008, 15 (12) :1554-1566
[7]  
Chameroy V, 1990, Int J Card Imaging, V5, P261, DOI 10.1007/BF01797843
[8]   The JPEG2000 still image coding system: An overview [J].
Christopoulos, C ;
Skodras, A ;
Ebrahimi, T .
IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2000, 46 (04) :1103-1127
[9]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[10]   Evaluation of irreversible compression of digitized posterior-anterior chest radiographs [J].
Erickson, BJ ;
Manduca, A ;
Persons, KR ;
Earnest, F ;
Hartman, TE ;
Harms, GF ;
Brown, LR .
JOURNAL OF DIGITAL IMAGING, 1997, 10 (03) :97-102