35 years of photovoltaics: Analysis of the TISO-10-kW solar plant, lessons learnt in safety and performance-Part 1

被引:56
作者
Virtuani, Alessandro [1 ]
Caccivio, Mauro [2 ]
Annigoni, Eleonora [1 ]
Friesen, Gabi [2 ]
Chianese, Domenico [2 ]
Ballif, Christophe [1 ]
Sample, Tony [3 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Microengn IMT, Photovolta & Thin Film Elect Lab PV LAB, Rue Maladiere 71b, CH-2000 Neuchatel, Switzerland
[2] SUPSI, Inst Appl Sustainabil Built Environm, Lugano, Switzerland
[3] European Commiss, European Solar Test Installat, Joint Res Ctr, Ispra, Italy
来源
PROGRESS IN PHOTOVOLTAICS | 2019年 / 27卷 / 04期
关键词
crystalline silicon; durability; long-term performance; reliability; solar modules; wear-out mechanisms; DEGRADATION; EXPOSURE; MODULES; CLIMATE;
D O I
10.1002/pip.3104
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The TISO-10-kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only -0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (-0.54%/y), median (-0.62%/y), and mean (-0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (similar to 70% if considering a +/- 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.
引用
收藏
页码:328 / 339
页数:12
相关论文
共 34 条
  • [1] Abenante L, 2010, 25 EUR PHOT SOL EN C
  • [2] [Anonymous], 1981, 162300 ASI
  • [3] [Anonymous], 1981, 95540281 DOEJPL
  • [4] Belmont J, 2014, C P 40 IEEE PHOT SPE
  • [5] Camani M, 1985, P MELECON 85 MED EL, VIV
  • [6] Camani M, 1992, 11 EC PHOT SOL EN C
  • [7] Camani M, 1985, 6 EC PHOT EN C LOND
  • [8] Ceppi P, 1986, 7 EC PHOT SOL EN C S
  • [9] Ceppi P, 1983, 5 EC PHOT SOL EN C A
  • [10] Chianese D, 2003, 3 WORLD C PHOT EN CO