Cerebral blood flow with [15O] water PET studies using an image-derived input function and MR-defined carotid centerlines

被引:53
作者
Fung, Edward K. [1 ]
Carson, Richard E. [1 ]
机构
[1] Yale Univ, Dept Biomed Engn, New Haven, CT 06520 USA
关键词
POSITRON-EMISSION-TOMOGRAPHY; PARTIAL VOLUME CORRECTION; MARKOV RANDOM-FIELD; HIGH-RESOLUTION; MOTION-COMPENSATION; METABOLIC-RATE; BRAIN; SEGMENTATION; RECONSTRUCTION; ARTERY;
D O I
10.1088/0031-9155/58/6/1903
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain and are often visible in brain PET images. We have devised a method of delineating the internal carotids in co-registered magnetic resonance (MR) images using the level-set method and applying the segmentations to PET images using a novel centerline approach. Centerlines of the segmented carotids were modeled as cubic splines and re-registered in PET images summed over the early portion of the scan. Using information from the anatomical center of the vessel should minimize partial volume and spillover effects. Centerline time-activity curves were taken as the mean of the values for points along the centerline interpolated from neighboring voxels. A scale factor correction was derived from calculation of cerebral blood flow (CBF) using gold standard arterial blood measurements. We have applied the method to human subject data from multiple injections of [O-15] water on the HRRT. The method was assessed by calculating the area under the curve (AUC) of the IDIF and the CBF, and comparing these to values computed using the gold standard arterial input curve. The average ratio of IDIF to arterial AUC (apparent recovery coefficient: aRC) across 9 subjects with multiple (n = 69) injections was 0.49 +/- 0.09 at 0-30 s post tracer arrival, 0.45 +/- 0.09 at 30-60 s, and 0.46 +/- 0.09 at 60-90 s. Gray and white matter CBF values were 61.4 +/- 11.0 and 15.6 +/- 3.0 mL/min/100 g tissue using sampled blood data. Using IDIF centerlines scaled by the average aRC over each subjects' injections, gray and white matter CBF values were 61.3 +/- 13.5 and 15.5 +/- 3.4 mL/min/100 g tissue. Using global average aRC values, the means were unchanged, and intersubject variability was noticeably reduced. This MR-based centerline method with local re-registration to [O-15] water PET yields a consistent IDIF over multiple injections in the same subject, thus permitting the absolute quantification of CBF without arterial input function measurements.
引用
收藏
页码:1903 / 1923
页数:21
相关论文
共 42 条
[1]  
[Anonymous], 1999, Level Set Methods and Fast Marching Methods: Evolving Interfaces in Computational Geometry, Fluid Mechanics, Computer Vision, and Materials Science
[2]   Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies [J].
Asselin, MC ;
Cunningham, VJ ;
Amano, S ;
Gunn, RN ;
Nahmias, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06) :1033-1054
[3]   A variational method in image recovery [J].
Aubert, G ;
Vese, L .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1997, 34 (05) :1948-1979
[4]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[5]   Markov random field and Gaussian mixture for segmented MRI-based partial volume correction in PET [J].
Bousse, Alexandre ;
Pedemonte, Stefano ;
Thomas, Benjamin A. ;
Erlandsson, Kjell ;
Ourselin, Sebastien ;
Arridge, Simon ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20) :6681-6705
[6]  
Brix G, 1997, EUR J NUCL MED, V24, P779
[7]   Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT [J].
Carson, RE ;
Barker, WC ;
Liow, JS ;
Johnson, CA .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :3281-3285
[8]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[9]   Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function [J].
Chen, K ;
Bandy, D ;
Reiman, E ;
Huang, SC ;
Lawson, M ;
Feng, D ;
Yun, LS ;
Palant, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (07) :716-723
[10]  
CHOI Y, 1991, J NUCL MED, V32, P733