Infrared thermography and ultrasound C-scan for non-destructive evaluation of 3D carbon fiber materials: A comparative study

被引:7
作者
Zhang, Hai [1 ]
Genest, Marc [2 ]
Robitaille, Francois [3 ]
Maldague, Xavier [1 ]
West, Lucas [3 ]
Joncas, Simon [4 ]
Leduc, Catherine [4 ]
机构
[1] Univ Laval, Dept Elect & Comp Engn, Quebec City, PQ G1V 0A6, Canada
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
[3] Univ Ottawa, Ottawa, ON K1N 6N5, Canada
[4] Ecole Technol Super, Montreal, PQ, Canada
来源
THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXVII | 2015年 / 9485卷
关键词
carbon fiber; Infrared NDT; micro-defect; laser line thermography; laser spot thermography; ultrasound NDT; micro-lens;
D O I
10.1117/12.2176853
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
3D Carbon fiber polymer matrix composites (3D CF PMCs) are increasingly used for aircraft construction due to their exceptional stiffness and strength-to-mass ratios. However, defects are common in the 3D combining areas and are challenging to inspect. In this paper, Stitching is used to decrease these defects, but causes some new types of defects. Infrared NDT (non-destructive testing) and ultrasound NDT are used. In particular, a micro-laser line thermography technique (micro-LLT) and a micro-laser spot thermography (micro-LST) with locked-in technique are used to detect the micro-defects. In addition, a comparative study is conducted by using pulsed thermography (PT), vibrothermography (VT). In order to confirm the types of the defects, microscopic inspection is carried out before NDT work, after sectioning and polishing a small part of the sample.
引用
收藏
页数:15
相关论文
共 11 条
[1]   OPTOACOUSTIC AND PHOTOTHERMAL MATERIAL INSPECTION TECHNIQUES [J].
BUSSE, G .
APPLIED OPTICS, 1982, 21 (01) :107-110
[2]  
Castanedo ClementeIbarra., 2005, Quantitative subsurface defect evaluation by pulsed phase thermography: depth retrieval with the phase
[3]  
Duan Y., 2010, 10 INT C QUANT INFRA
[4]   Comparison between pulsed and modulated thermography in glass-epoxy laminates [J].
Giorleo, G ;
Meola, C .
NDT & E INTERNATIONAL, 2002, 35 (05) :287-292
[5]  
Ibarra-Castanedo C., 2013, HDB TECHNICAL DIAGNO, DOI [10.1007/978-3-642-25850-3_10, DOI 10.1007/978-3-642-25850-3_10]
[6]   Crack imaging by scanning laser-line thermography and laser-spot thermography [J].
Li, T. ;
Almond, D. P. ;
Rees, D. A. S. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (03)
[7]   Double pulse infrared thermography [J].
Maldague, X ;
Ziadi, A ;
Klein, M .
NDT & E INTERNATIONAL, 2004, 37 (07) :559-564
[8]  
Maldague XPV, 2001, WILEY MICRO, pXV
[9]  
Marinetti S, 1997, MATER EVAL, V55, P407
[10]   PHOTOTHERMAL RADIOMETRY [J].
NORDAL, PE ;
KANSTAD, SO .
PHYSICA SCRIPTA, 1979, 20 (5-6) :659-662